Automatic laser shutdown is a procedure to automatically shut down the laser when there is no input light and stop emitting optical signals. For example, when an optical interface board does not bear services, a fiber fault occurs, or the
received optical signals are lost, the laser is automatically off. This reduces the on period of the laser, extends the service life of the laser, and avoids exposure to hazardous levels.
Prerequisites
The OTU board must be created.
Procedure
- In the NE Explorer, select a board and choose from the Function Tree. Select the By Function option
button.
- Select Primary, Secondary State from the drop-down list.
- Select the unit port. Click State and choose OOS to set the Primary, Secondary State.
- Select Automatic Laser Shutdown from the drop-down list. Click Query and the attribute of Automatic Laser Shutdown for the port or path are shown in the window.
- Select an optical interface and set Automatic Laser Shutdown to ENABLE.

- Click Apply.
- Select Primary, Secondary State from the drop-down list.
- Select the unit port. Click State and choose IS to set the Primary, Secondary State.