This section takes a network formed by two OTM stations as an example to describe the test procedure of the intra-board 1+1 protection switching that is implemented by using the OLP.
Tools, Equipment and Materials
U2000 Web LCT, signal analyzer, optical fiber, flange, optical attenuator
Set-up Diagram
The diagram of testing intra-board 1+1 protection switching is shown in Figure 1.
Figure 1 Testing intra-board 1+1 protection switching
: Fixed optical attenuator |
Procedure
- Connecting Test Instruments
- In station A, respectively connect the output and input optical interfaces of the signal analyzer to the input optical interface RX and output optical interface TX on the client side of the OTU with the fixed optical attenuator in between.
- In station B, connect the input optical interface RX and the output optical interface TX on the client side of the OTU with the fixed optical attenuator in between to realize the loopback on the client side, as shown in Figure 1.
- Test the channel by using a signal analyzer to ensure that no bit error is generated.
- Querying the Normal Channel Status of the Station A
- Log in to the U2000 Web LCT. Double-click the ONE icon in the Main Topology, and the status figure of the ONE is displayed.
- Right-click a NE icon and select NE Explorer to display the NE Explorer dialog box.
- Select the NE from the Navigator Tree in the left-hand pane and choose from the Function Tree.
- Click Query, a prompt appears to indicate that the operation was successful. Click Close. And all protection groups are listed in the protection group list in the right-hand pane. The switching
status of intra-board protection and channel status should be Idle.
- Check the channel status of the intra-board 1+1 protection. The Working Channel is 1(RI1/TO1) and the Protection Channel is 2(RI2/TO2). The Working Channel Status and the Protection Channel Status is Idle.
- Testing the Protection Switching of the Equipment
- The switching test of the intra-board protection can be performed in two ways.
- Method 1: fiber removing. Remove the fiber of the RI1 interface of the OLP board in Station A to perform the switching, as shown in Figure 1.
- Method 2: forced switching. In the protection group user interface of station A, right-click the desired protection group, and select Force to Protection Channel to perform the switching. Click OK in
the dialog box displayed.
NOTICE: In Method 1, you must disconnect the fiber that inputs signals to the OLP board in station A. Otherwise, protection switching may be performed twice or no protection switching is performed. In this way, the detected switching
time is more scientific.
- Query the channel states of the intra-board 1+1 protection in station A.
- Choose from the Function Tree. Click Query, a prompt appears to indicate that the operation was successful. Click Close.
- In the fiber removing mode, Working Channel is 1(RI1/TO1), and Protection Channel is 2(RI2/TO2).Working Channel Status is SF Switched, Protection Channel Status is Idle. Switching
Status is Switching.
- In the forced switching mode, Working Channel is 1 (RI1/TO1), and Protection Channel is 2 (RI2/TO2). Working Channel Status and the Protection Channel Status is Idle. Switching Status is Switching.
- In the NE panel of the Station A, right-click the OLP board and select Browse Current Alarms.
- If the protection group is automatically switched, the OLP board reports AUTOSW.
- If the protection group is forced switched, the OLP board reports FRCDSW.
- Test the services and switching time by using a signal analyzer. The services should be available, no bit error is generated, and the switching time should be less than 50 ms.
- To restore the test environment of the two switching modes in Step 1, the following two modes can be respectively used:
- Fiber removing mode: Reconnect the fiber.
- Forced switching mode: Right-click the desired protection group in the Protection Group, and select Clear. Click OK in the dialog box displayed.
NOTE: If the Restore Mode field is set to Non-Revertive, right-click the desired protection group and then
choose from the shortcut menu. After that, right-click the same protection group again and then choose from the shortcut
menu. Click OK in the dialog box displayed.
- Click Query, a prompt appears to indicate that the operation was successful. Click Close. And Switching Status of the protection group should be Idle.