This section describes the parameters involved in IPA configuration.
Field |
Value |
Description |
|---|---|---|
Band |
C Band, L Band |
The waveband where the carrier resides. |
Detection Card |
|
Specifies the slot number and optical port number of the optical power detection board. |
Shutdown Card |
|
Specifies the slot number and optical port number of the optical power control implementation board. |
Raman Amplifier |
|
Specifies the NE name and slot number where the Raman amplifier resides. If the Raman amplifier is optional, it is not used unless a Raman amplifier is used at the receive end. |
Enable/Disable |
Enabled, Disabled |
Sets whether to start using the IPA. |
Status |
New IPA Start, Alarm Available, Power off, Restart, Power on, IPA ended, Detect under the security mode, Unknown |
Displays the IPA status. |
Restart Mode |
Manual, Automatic |
Sets the IPA restart mode. |
Safe Control Switch |
On, Off |
Enabled: The IPA restart optical power is limited at a safe value. This increases the safety of the transmission. Disabled: The IPA restart optical power is not limited. |
Restart Pulse |
Enabled, Disabled |
If the IPA-related board detects an alarm, and determines that the fiber is cut off, the IPA function enables the board to shut down the laser of the control implementation board. Then it periodically restarts the laser of the control implementation board to detect whether the line is back to normal. When you create an IPA pair, this parameter can only be set to Enabled. After you configure the OSC as an auxiliary detection board, you can change the parameter to Disabled. If the pulse restart switch is set to disabled, the automatic restart function does not work. |
Off Duration (s) |
100 to 300 |
Displays the duration of laser shutdown. |
On Duration (s) |
1.75 to 45.0 |
Displays the duration of laser turn-on. In one IPA protection group, the On Duration (s) must be the same. This duration value changes depending on the number of intermediate stations in the IPA protection group. |
Testing Duration (s) |
80 to 100 Default: 80 |
Displays the time for IPA testing. |
Detection Card Alarm Threshold (dBm) |
-35.0 to -14.0 Default: -30.0 |
Configure this field when the system is configured with a Raman Amplifier. When there is a Raman amplifier, re-set the threshold of the detection board (such as the OAU1). How to set the threshold: First test the input optical power A of the optical amplifier behind the Raman board when the services are normal. Then interrupt the services (by shutting down the laser of the upstream amplifier), open the Raman board, and obtain the input optical power B of the optical amplifier. (A+B)/2 is recommended. |
Raman Card Threshold (dBm) |
-60.0 to 0.0 Default:0.0 |
Configure this field when the system is configured with a Raman Amplifier. How to set the threshold:
|
Raman Alarm |
Yes, No |
Set whether to use Raman board as the auxiliary detection board. If Raman board alarm is Yes, the Raman board is also used as an auxiliary detection board. Otherwise, it is not used as an auxiliary detection board. When the Raman board is used as an auxiliary detection board, other boards must be configured as the auxiliary detection boards at the same time and there must be a supervisory channel unit in the auxiliary detection boards. |
Enable Auto Laser Shutdown at Raman Card |
Enabled, Disabled |
Set whether to enable the auto laser shutdown function of the raman card or not. |
Auxiliary Raman Card |
|
Displays the auxiliary Raman card of the IPA. |
ROP Card |
|
Displays the ROP card of the IPA. |
Auxiliary Detection Card |
|
Displays the auxiliary detection board of the IPA. |
| Number of the OLA between two nodes | 0 | 5 | 10 | 15 | 20 | 25 | >25 |
|---|---|---|---|---|---|---|---|
| On Duration (s) | 3 | 15 | 20 | 25 | 35 | 40 | 45 |