Following is the description of the parameters of ODUk SNCP protection.
Table 1 lists the parameters involved in the configuration of ODUk SNCP protection.
Table 2 lists the parameters involved in query and modification of ODUk SNCP protection status.
Field |
Value |
Description |
|---|---|---|
Protection Type |
SW SNCP, ODUk SNCP |
Specifies the level of the new service. |
SNCP Type |
|
Displays the protection type of the service.
|
Service Type |
For SW SNCP: GE, 10GE, FE, OTU1, OTU2, OTU3, OTU5G, STS3, STS12, STS48, STS192, STS768, FC100, FC200, FC400, FC1200, FICON, FICON Express, HDTV, DVB-ASI, DVB-SDI, ESCON, FDDI For ODUk SNCP: ODU0, ODU1, ODU2, ODU3 |
Specifies the service type of the new service. |
OTN Level |
|
Displays the monitoring layer of SNCP. |
Revertive Mode |
Revertive, Non-Revertive Default: Non-Revertive |
Chooses whether the service is switched to the original working path after the failure is eliminated. If you want the service to be switched back to the original working path then, select Revertive. If you do not want the service to be switched back then, select Non-Revertive. The default value is recommended. |
WTR Time (s) |
300-720 Default: 300 |
Sets the wait-to-restore time. It is the time interval between the time when the working service is detected to be normal after switching and the time when the service is switched back to the working path. You can modify the WTR Time (s) only when the value of Revertive Mode is Revertive. The default value is recommended. |
| Working Channel Hold-Off Time (100ms)/Protection Channel Hold-Off Time (100 ms) | 0-100 Default: 0 |
Sets the time interval between the time when the system detects signal degrade and the time when the service switching occurs, in order to avoid repeated switching when the service status is not stable. The switching delay time is in 100 milliseconds. For example, if you enter 5, the delay time is 500 milliseconds. Sets the delay time. To avoid the repeated switching when the service status is not stable, generally the delay time needs to be set. Especially in the network of multi-protection cascading, to avoid that the switching occurs to downstream protections at the same time, the delay time needs to be set for downstream protections. The hold-off time of the working and protection channels can be set respectively. |
SD Switching |
Enabled, Disabled Default: Disabled |
Sets whether SD can trigger the protection switch. |
Direction |
Unidirectional, Bidirectional Default: Unidirectional |
Sets whether the service is bidirectional or unidirectional. |
Remarks |
For example: ODUkSNCP-SRV1 |
Indicates the protection group memo information. It is a string with a maximum length of 64 characters. |
Source Slot |
Slot-Board Name |
Displays the source slot of the cross-connection. |
Source Optical Port |
Port No. (Port name) |
Displays the source port of the cross-connection. |
Source Optical Channel |
Optical path No. |
Displays the source path of the cross-connection. |
Sink Slot |
Slot-Board Name |
Displays the sink slot of the cross-connection. |
Sink Optical Port |
Port No. (Port name) |
Displays the sink port of the cross-connection. |
Sink Optical Channel |
Slot-Optical port No.-Optical path No. |
Displays the sink path of the cross-connection. |
| ODUflex Timeslots | 3 to 7 | Indicates the quantity of ODUflex timeslots. NOTE:
|
Field |
Value |
Description |
|---|---|---|
Source Channel |
Source Channel Number-Source Slot Number-Source Port Number-Source Optical Channel Number |
Displays the source timeslot of the service. |
Service Sink |
Sink Channel Number-Sink Slot Number-Sink Port Number-Sink Optical Channel Number |
Displays the sink timeslot of the service. |
| Protection Type | SW SNCP, SNC/I, SNC/N, SNC/S | Displays the type of a service. |
Level |
GE, Any, ODU1, ODU2 |
Displays the level of a service. |
OTN Level |
|
Displays the monitoring layer of SNCP. |
Revertive Mode |
Revertive, Non-Revertive Default: Non-Revertive |
Displays the revertive mode that indicates whether services are switched back from the protection channel after the working channel is normal. The default value is recommended. |
WTR Time (s) |
300-720 Default: 300 |
Sets the wait-to-restore time. It is the time interval between the time when the working service is detected to be normal after switching and the time when the service is switched back to the working path. You can modify the WTR Time (s) only when the value of Revertive Mode is Revertive. The default value is recommended. |
Working Channel Hold-Off Time (100ms) |
0-100 Default: 0 |
Sets the time interval between the time when the system detects signal degrade and the time when the service switching occurs, in order to avoid repeated switching when the service status is not stable. The switching delay time is expressed in 100 milliseconds. For example, if you enter 5, the delay time is 500 milliseconds. Sets the delay time. To avoid the repeated switching when the service status is not stable, generally the delay time needs to be set. Especially in the network of multi-protection cascading, to avoid that the switching occurs to downstream protections at the same time, the delay time needs to be set for downstream protections. |
| SD Switching | Enabled, Disabled |
Sets whether SD can trigger the protection switch. |
SD Trigger Condition |
- |
Display the SD trigger condition. |
Current Status |
|
Displays the switching status of the current protection group. |
| Current Channel | Working Channel, Protection Channel, Delay Start, Unknown |
Displays whether the working service or the protection service is selectively received. |