Client 1+1 Protection
- Introduction to Client 1+1 Protection
The client 1+1 protection is configured with one working wavelength and one protection wavelength that are transmitted in two different routes to protect the OTU board and OCh fiber. The client 1+1 protection protects the OTU board and OCh fibers by using the dual fed and selective receiving function of the OLP/SCS/DCP board.
- Availability
This section describes the equipment type that support the client 1+1 protection function.
- Function Implementation
Client-side 1+1 protection uses two wavelengths: one is the working wavelength, and the other is the protection wavelength. The two wavelengths adopt diverse routing to transmit signals to protect the OTU and the OCh fibers.
- Application of Client 1+1 Protection
This section describes the application of the client 1+1 protection.
- Configuring Client 1+1 Protection
This section describes the configuration of client 1+1 protection, including how to create, delete and modify parameters as well as the description of parameters.
- Verifying Client 1+1 Protection Switching
This section takes a network formed by two OTM stations as an example to describe the test procedure of the client 1+1 protection switching that is realized by using the OLP.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.