This section describes the configuration of tributary SNCP protection, including how to create, delete, and modify parameters as well as the description of parameters.
Configuration Principle
This section describes the principle of configuring the tributary SNCP protection.
Creating the Tributary SNCP Service
The tributary SNCP protection protects the client services that are accessed by the tributary board. The cross-connection granularity is the ODUk service. Currently, the tributary SNCP is realized by the line board and the tributary board that has the ODUk integrated cross-connection chip.