Configuration Principle

This section describes the principle of configuring the SW SNCP protection.

NOTE:
OptiX OSN 8800 T32(NA) and OptiX OSN 8800 T64(NA) do not support this function.

The principles of configuring the SW SNCP protection are as follows:

In the case of OptiX OSN 3800A,
In the case of OptiX OSN 6800A,
NOTE:

In the case of OptiX OSN 6800A, paired slots are 1&2, 3&4, 5&6, 7&8, 11&12, 13&14, and 15&16.

NOTICE:
  • In terms of configuring the SW SNCP services of the L4G and TBE board, note the following rules.
    • Other than the general configuration of dual fed and selective receiving function, the Ethernet interface attributes and Ethernet private line services need to be configured. (For how to configure the Ethernet interface attributes and Ethernet private line services, refer to Configuration Guide.)
    • The client-side service attributes (for example, working mode of the Ethernet) of the corresponding channels of active and standby boards must be the same.

In the case of the OptiX OSN 1800 (NA),

The two OTU boards where the working and protection channels reside should have the cross-connection and convergence function, such as the LQM2 and LQG.