With the port mirroring function, you can observe the service packets on the port without interrupting services. This facilitates the operations, such as test, service activation, routine maintenance and in-service commissioning.
Applicable to the 11LEX4, 11LEM24, TBE and L4G of the OptiX OSN 8800 T32(NA), OptiX OSN 8800 T64(NA), OptiX OSN 3800A and OptiX OSN 6800A.
Setting the parameters of a port affect the service of the board. Before setting the parameters of a port, configure State of the port as OOS at the Ethernet Interface. After setting the parameters, restore State of the port to IS.


For the TBE board, you can set Uplink Listened Port and Downlink Listened Port at the same time, or one of them.
For the L4G board, only Uplink Listened Port is supported.
Do not select a port where services exist from the Mirror Listener Port drop-down list. Otherwise, creating port mirroring fails.