Configuration Process

This section describes the process of configuration between station A and station C. For the configuration of other stations, refer to the description for station C.

Background Information

The NE-level optical cross-connection is adopted. Before configuration, fiber connection on the U2000 Web LCT system should be completed.
NOTE:

The path between FIUs is created in the example. The FIUs are the fixed edge point. Hence, the edge point does not need to be configured after fiber connection. Otherwise the corresponding ports need be configured as edge points.

Table 1 and Table 2 shows the connected fibers. After fiber connection, it is not required to configure edge ports. If single-board-level optical cross-connection is adopted, it is required to set ports as edge ports in advance.
Table 1 Fiber connection of station A

Direction

Source NE

Source Port

Sink NE

Sink Port

Single-Fiber Unidirectional

NE180

101-FIU-3(TC)

NE180

103-OAU1-1(IN)

Single-Fiber Unidirectional

NE180

103-OAU1-5(TDC)

NE180

103-OAU1-5(RDC)

Single-Fiber Unidirectional

NE180

103-OAU1-4(OUT)

NE180

105-WSD9-1(IN)

Single-Fiber Unidirectional

NE180

105-WSD9-10(DM8)

NE180

207-RMU9-10(AM8)

Single-Fiber Unidirectional

NE180

207-RMU9-11(TOA)

NE180

203-OAU1-1(IN)

Single-Fiber Unidirectional

NE180

203-OAU1-5(TDC)

NE180

203-OAU1-5(RDC)

Single-Fiber Unidirectional

NE180

203-OAU1-4(OUT)

NE180

201-FIU-3(RC)

Single-Fiber Unidirectional

NE180

301-LSX-1(OUT)

NE180

109-RMU9-3(AM1)

Single-Fiber Unidirectional

NE180

109-RMU9-11(TOA)

NE180

114-OAU1-1(IN)

Single-Fiber Unidirectional

NE180

114-OAU1-5(TDC)

NE180

114-OAU1-5(RDC)

Single-Fiber Unidirectional

NE180

114-OAU1-4(OUT)

NE180

115-FIU-3(RC)

Single-Fiber Unidirectional

NE180

105-WSD9-9(DM7)

NE180

210-RMU9-10(AM8)

Single-Fiber Unidirectional

NE180

210-RMU9-11(TOA)

NE180

215-OAU1-1(IN)

Single-Fiber Unidirectional

NE180

215-OAU1-5(TDC)

NE180

215-OAU1-5(RDC)

Single-Fiber Unidirectional

NE180

215-OAU1-4(OUT)

NE180

216-FIU-3(RC)

Table 2 Fiber connection of station C

Direction

Source NE

Source Port

Sink NE

Sink Port

Single-Fiber Unidirectional

NE182

101-FIU-3(TC)

NE182

103-OAU1-1(IN)

Single-Fiber Unidirectional

NE182

103-OAU1-5(TDC)

NE182

103-OAU1-5(RDC)

Single-Fiber Unidirectional

NE182

103-OAU1-4(OUT)

NE182

105-WSD9-1(IN)

Single-Fiber Unidirectional

NE182

105-ROAM-2(EXPO)

NE182

109-ROAM-3(EXPI)

Single-Fiber Unidirectional

NE182

109-ROAM-4(OUT)

NE182

114-OAU1-1(IN)

Single-Fiber Unidirectional

NE182

114-OAU1-4(OUT)

NE182

115-FIU-3(RC)

Single-Fiber Unidirectional

NE182

105-ROAM-5(DM)

NE182

201-D40-1(IN)

Single-Fiber Unidirectional

NE182

201-D40-5(D04)

NE182

204-LSX-1(IN)

Single-Fiber Unidirectional

NE182

201-D40-6(D05)

NE182

205-LSX-1(IN)

Single-Fiber Unidirectional

NE182

214-OAU1-5(TDC)

NE182

214-OAU1-5(RDC)

Single-Fiber Unidirectional

NE182

206-LSX-1(OUT)

NE182

109-ROAM-9(A04)

For details of fiber connection, refer to .

Procedure

  1. Station A Configuration Process
    1. Click the NE180 in the NE Explorer, and choose Configuration > Optical Cross-Connection Management from the Function Tree. Click NE-Level Optical Cross-Connection tab in the right-hand interface.
    2. Click Create. The Create NE-Level Optical Cross-Connection window is displayed. Set the pass-through service from west to north at station A for the service 12/1533.47/195.50 from station D to station F.
    3. Select the source slot, sink slot, source port and sink port from the drag list. Click the button on the right of Source Wavelength or Sink Wavelength. Open the Select Wavelength window. Select the wavelengths from the Available Wavelengths list. Click to add the needed wavelengths to Selected Wavelengths.

    4. Click OK and the wavelength selection is completed. The Create NE-Level Optical Cross-Connection window is displayed.

    5. Click Apply.
    6. Repeat step b to step e to create the pass-through service from west to south at station A for the service 10/1532.68/195.60 from station D to station E.

    7. Repeat step b to step e to create the service added from the east at station A for the service 18/1535.82/195.20 from station A to station B.

    8. The created optical cross-connection is displayed in the interface.
  2. Station C Configuration Process
    1. Click the NE182 in the NE Explorer, and choose Configuration > Optical Cross-Connection Management from the Function Tree. Click NE-Level Optical Cross-Connection tab in the right-hand interface.
    2. Click Create. The Create NE-Level Optical Cross-Connection window is displayed. Set the pass-through service from west to east at station C for the service 12/1533.47/195.50 from station B to station D.
    3. Select the source slot, sink slot, source port and sink port from the drag list. Click the button on the right of Source Wavelength or Sink Wavelength. Open the Select Wavelength window. Select the wavelengths from the Available Wavelengths list. Click to add the needed wavelengths to Selected Wavelengths.

    4. Click OK and the wavelength selection is completed. The Create NE-Level Optical Cross-Connection window is displayed.

    5. Click Apply.
    6. Repeat step b to step e to create two services dropped from the west at station C for the services 10/1532.68/195.60 and 8/1531.90/195.70 from station B to station C.

    7. Repeat step b to step d to create the service added from the east at station C for the service 8/1531.90/195.70 from station C to station D.