This section describes the process of configuration between station A and station C. For the configuration of other stations, refer to the description for station C.
The path between FIUs is created in the example. The FIUs are the fixed edge point. Hence, the edge point does not need to be configured after fiber connection. Otherwise the corresponding ports need be configured as edge points.
Direction |
Source NE |
Source Port |
Sink NE |
Sink Port |
|---|---|---|---|---|
Single-Fiber Unidirectional |
NE180 |
101-FIU-3(TC) |
NE180 |
103-OAU1-1(IN) |
Single-Fiber Unidirectional |
NE180 |
103-OAU1-5(TDC) |
NE180 |
103-OAU1-5(RDC) |
Single-Fiber Unidirectional |
NE180 |
103-OAU1-4(OUT) |
NE180 |
105-WSD9-1(IN) |
Single-Fiber Unidirectional |
NE180 |
105-WSD9-10(DM8) |
NE180 |
207-RMU9-10(AM8) |
Single-Fiber Unidirectional |
NE180 |
207-RMU9-11(TOA) |
NE180 |
203-OAU1-1(IN) |
Single-Fiber Unidirectional |
NE180 |
203-OAU1-5(TDC) |
NE180 |
203-OAU1-5(RDC) |
Single-Fiber Unidirectional |
NE180 |
203-OAU1-4(OUT) |
NE180 |
201-FIU-3(RC) |
Single-Fiber Unidirectional |
NE180 |
301-LSX-1(OUT) |
NE180 |
109-RMU9-3(AM1) |
Single-Fiber Unidirectional |
NE180 |
109-RMU9-11(TOA) |
NE180 |
114-OAU1-1(IN) |
Single-Fiber Unidirectional |
NE180 |
114-OAU1-5(TDC) |
NE180 |
114-OAU1-5(RDC) |
Single-Fiber Unidirectional |
NE180 |
114-OAU1-4(OUT) |
NE180 |
115-FIU-3(RC) |
Single-Fiber Unidirectional |
NE180 |
105-WSD9-9(DM7) |
NE180 |
210-RMU9-10(AM8) |
Single-Fiber Unidirectional |
NE180 |
210-RMU9-11(TOA) |
NE180 |
215-OAU1-1(IN) |
Single-Fiber Unidirectional |
NE180 |
215-OAU1-5(TDC) |
NE180 |
215-OAU1-5(RDC) |
Single-Fiber Unidirectional |
NE180 |
215-OAU1-4(OUT) |
NE180 |
216-FIU-3(RC) |
Direction |
Source NE |
Source Port |
Sink NE |
Sink Port |
|---|---|---|---|---|
Single-Fiber Unidirectional |
NE182 |
101-FIU-3(TC) |
NE182 |
103-OAU1-1(IN) |
Single-Fiber Unidirectional |
NE182 |
103-OAU1-5(TDC) |
NE182 |
103-OAU1-5(RDC) |
Single-Fiber Unidirectional |
NE182 |
103-OAU1-4(OUT) |
NE182 |
105-WSD9-1(IN) |
Single-Fiber Unidirectional |
NE182 |
105-ROAM-2(EXPO) |
NE182 |
109-ROAM-3(EXPI) |
Single-Fiber Unidirectional |
NE182 |
109-ROAM-4(OUT) |
NE182 |
114-OAU1-1(IN) |
Single-Fiber Unidirectional |
NE182 |
114-OAU1-4(OUT) |
NE182 |
115-FIU-3(RC) |
Single-Fiber Unidirectional |
NE182 |
105-ROAM-5(DM) |
NE182 |
201-D40-1(IN) |
Single-Fiber Unidirectional |
NE182 |
201-D40-5(D04) |
NE182 |
204-LSX-1(IN) |
Single-Fiber Unidirectional |
NE182 |
201-D40-6(D05) |
NE182 |
205-LSX-1(IN) |
Single-Fiber Unidirectional |
NE182 |
214-OAU1-5(TDC) |
NE182 |
214-OAU1-5(RDC) |
Single-Fiber Unidirectional |
NE182 |
206-LSX-1(OUT) |
NE182 |
109-ROAM-9(A04) |
For details of fiber connection, refer to .
button
on the right of Source Wavelength or Sink Wavelength. Open the Select Wavelength window.
Select the wavelengths from the Available Wavelengths list. Click
to
add the needed wavelengths to Selected Wavelengths.



button
on the right of Source Wavelength or Sink Wavelength. Open the Select Wavelength window.
Select the wavelengths from the Available Wavelengths list. Click
to
add the needed wavelengths to Selected Wavelengths.