Configuration Process

This section considers station A as an example to describe the configuration process of the 52TOM board.

Precautions

NOTE:

The OptiX OSN 6800A and OptiX OSN 3800A do not support ODU1_ODU0 mode (OTU1->ODU1->ODU0) in non-cascading mode.

NOTE:
  • A ClientLP port can access only one service that has a rate higher than 1.25 Gbit/s, and this service can be configured in only the first channel of the ClientLP port.
  • The client-side eight pairs of optical interfaces can access services at a maximum rate of 10 Gbit/s.
NOTE:

The client-side optical interfaces can be selected as required.

Procedure

  1. Set the Working Mode of the 52TOM board. In the NE Explorer, select a 52TOM board, and choose Configuration > Working Mode from the Function Tree. Set Board Working mode to Non-Cascading and then set Port Working Mode to ODU1_ODU0 mode (OTU1->ODU1->ODU0). For details, see Configuring the Working Mode of the 52TOM Board.
  2. In the NE Explorer, select the desired board , and choose Configuration > WDM Interface from the Function Tree. Set the Service Mode of the client-side interface of 52TOM as OTN mode. For details, refer to Configuring the Service Mode.

    NOTE:

    When the 52TOM board accesses OTU1 services on the client side, you first need to set the Service Mode of the 52TOM board to OTN mode.

  3. In the NE Explorer, select the desired board , and choose Configuration > WDM Interface from the Function Tree. Configure the Service Type at the WDM interface of the 52TOM as OTU1. For details, see Configuring the Service Type.
  4. Configure the OTU1 cross-connection between the RX/TX and ClientLP interfaces on the 52TOM board.
    1. Configure an OTU1 cross-connection between the 3(RX1/TX1) interface and the 201(ClientLP1/ClientLP1) interface on 52TOM board.

      Parameters Value

      Level

      OTU1

      Service Type

      -

      Direction

      Bidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      3(RX1/TX1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-15-52TOM

      Sink Optical Port

      201(ClientLP1/ClentLP1)

      Sink Optical Channel (eg.1,3-6)

      1

      NOTE:

      The Service Type must be the same as the Service Type at the WDM interface of the 52TOM board.

    2. Repeat 4.a to configure the remaining OTU1 services.
  5. Configure ODU0 cross-connections between the 52TOM and 52NS2 boards.
    1. Configure an ODU0 cross-connection between the 161(ODU0LP1/ODU0LP1) interface on 52TOM board and the 161(ODU0LP1/ODU0LP1) interface on 52NS2 board.

      Parameters Value

      Level

      ODU0

      Service Type

      -

      Direction

      Bidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      161(ODU0LP1/ODU0LP1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-12-52NS2

      Sink Optical Port

      161(ODU0LP1/ODU0LP1)

      Sink Optical Channel (eg.1,3-6)

      1

    2. Repeat 5.a to configure ODU0 cross-connections between other 52TOM and 52NS2 boards.