Configuration Process

This section considers station A as an example to describe the configuration process of the 52TOM board.

Precautions

NOTE:
  • In Non-Cascading ODU0 mode (Any->ODU0[->ODU1]) mode, the OptiX OSN 8800 T16(NA), OptiX OSN 8800 T32(NA) and OptiX OSN 8800 T64(NA) cannot groom the ODU1 service.
  • In Non-Cascading ODU0 mode (Any->ODU0[->ODU1]) mode, the OptiX OSN 6800A/3800A cannot groom the ODU0 service.
NOTE:
  • The total rate of services that are input through each group of ClientLP ports must not be higher than 1.25 Gbit/s.
  • Only one GE service can be input through each group of ClientLP ports.
NOTE:
  • When the number of a route of the ClientLP1, ClientLP3, ClientLP5, or ClientLP7 port is the same as that of a route of the ClientLP2, ClientLP4, ClientLP6, or ClientLP8 port, the two routes cannot be configured with cross-connections at the same time. For example, if the 201(ClientLP1/ClientLP1)-1 service type is configured, the 202(ClientLP2/ClientLP2)-1 service type must not be configured.
  • The client-side eight pairs of optical interfaces can access services at a maximum rate of 10 Gbit/s.

Procedure

  1. Set the Working Mode of the 52TOM board. In the NE Explorer, select a 52TOM board, and choose Configuration > Working Mode from the Function Tree. Set Board Working mode to Non-Cascading and then set Port Working Mode to ODU0 mode (Any->ODU0[->ODU1]). For details, see Configuring the Working Mode of the 52TOM Board.
  2. In the NE Explorer, select the desired board , and choose Configuration > WDM Interface from the Function Tree. Configure the Service Type at the WDM Interface of the 52TOM. For details, see Configuring the Service Type.
  3. Configure the cross-connections for the eight Any services that are input to the 52TOM board.

    NOTE:

    In this scenario, for Any services, only the FE, GE, FC100, FICON, DVB-AS, DVB-SDI, ESCON, and FDDI services can be accessed.

    1. Configure the cross-connections from the RX/TX ports to the ClientLP ports on the 52TOM board for the Any services that are input to the board.

      NOTE:

      In this scenario, for Any services, only the FE, GE, FC100, FICON, DVB-AS, DVB-SDI, ESCON, and FDDI services can be accessed.

      Parameters Value

      Level

      ANY

      Service Type

      FE

      Direction

      Bidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      3(RX1/TX1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-15-52TOM

      Sink Optical Port

      201(ClientLP1/ClentLP1)

      Sink Optical Channel (eg.1,3-6)

      1

      NOTE:

      The Service Type must be the same as the Service Type at the WDM port of the 52TOM board.

    2. Repeat 3.a to configure the remaining Any services.
  4. Configure cross-connections for the two ODU0 services between the 52TOM and 52NS2 boards.

    NOTE:

    In Non-Cascading ODU0 mode (Any->ODU0[->ODU1]) mode, only the OptiX OSN 8800 T16(NA), OptiX OSN 8800 T32(NA) and OptiX OSN 8800 T64(NA) supports this scenario.

    1. Configure a cross-connection for one ODU0 service between the 52TOM and 52NS2 boards.

      Parameters Value

      Level

      ODU0

      Service Type

      -

      Direction

      Bidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      201(ClientLP1/ClentLP1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-12-52NS2

      Sink Optical Port

      161(ODU0LP1/ODU0LP1)

      Sink Optical Channel (eg.1,3-6)

      1

    2. Repeat 4.a to configure a cross-connection for the other ODU0 service between the 52TOM and 52NS2 boards.
  5. Configure cross-connections for the two ODU1 services between the 52TOM and 52NS2 boards.

    NOTE:

    In Non-Cascading ODU0 mode (Any->ODU0[->ODU1]) mode, only the OptiX OSN 6800A/3800A supports this scenario.

    Parameters Value

    Level

    ODU1

    Service Type

    -

    Direction

    Bidirectional

    Source Slot

    Shelf2(Subrack2)-15-52TOM

    Source Optical Port

    161(ODU0LP1/ODU0LP1)

    Source Optical Channel (eg.1,3-6)

    1

    Sink Slot

    Shelf2(Subrack2)-12-52NS2

    Sink Optical Port

    51(ODU1LP/ODU1LP)

    Sink Optical Channel (eg.1,3-6)

    1

    NOTE:

    Configure the ODU0 cross-connections from the ClientLP ports to the ODU0LP ports on the 52TOM board automatically, when configure the ODU1 cross-connections.