This section considers station A as an example to describe the configuration process of the 52TOM board.
Precautions
NOTE:
The client-side six pairs of optical interfaces can access services at a maximum rate of 2.5 Gbit/s.
For the client services at a rate of greater than 1.25 Gbit/s, the client-side interfaces can access up to only one channel. And this service can be configured in only the first ClientLP port.
In cascade mode, only RX7/TX7 and RX8/TX8 can be used as the WDM-side optical interfaces.
Procedure
Set the Working Mode of the 52TOM board. In the NE Explorer, select a 52TOM board, and choose Configuration > Working Mode from the Function Tree. Set Board Working mode to Cascading and then set Port Working Mode to ODU1 tributary-line mode (OTU1/Any->ODU1->OTU1). For details, refer to Configuring the Working Mode of the 52TOM Board.
In the Path Views, set the type of client-side ports 9 (RX7/TX7) and 10 (RX8/TX8) to Line Side Color Optical Port. For details, refer to Modifying Ports.
NOTE:
When the 52TOM board is used as a tributary & line board, the Type of this optical interface must be changed to Line Side Color Optical Port.
In the NE Explorer, select the desired board , and choose Configuration > WDM Interface from the Function Tree. Configure the Service Type at the WDM Interface of the 52TOM. For details, refer to Configuring the Service Type.
Configure the cross-connections from the RX/TX ports to the ClientLP ports on the 52TOM board for the Any services of the board.
Configure the cross-connections from the RX/TX ports to the ClientLP ports on the 52TOM board for the Any services of the board.
Parameters
Value
Level
ANY
Service Type
FE
Direction
Bidirectional
Source Slot
Shelf2(Subrack2)-15-52TOM
Source Optical Port
3(RX1/TX1)
Source Optical Channel (eg.1,3-6)
1
Sink Slot
Shelf2(Subrack2)-15-52TOM
Sink Optical Port
201(ClientLP1/ClientLP1)
Sink Optical Channel (eg.1,3-6)
1
NOTE:
The Service Type must be the same as the Service Type at the WDM interface of the 52TOM board.
Repeat 4.a to configure the remaining Any services.
Configure two separate cross-connections from the internal logical port to ports 9 (RX7/TX7) and 10 (RX8/TX8) for the 52TOM board to achieve dual feeding.
Configure two separate cross-connections from the internal logical port to ports 9 (RX7/TX7) and 10 (RX8/TX8) for the 52TOM board to achieve dual feeding.
Parameters
Value
Level
OTU1
Service Type
-
Direction
Bidirectional
Source Slot
Shelf2(Subrack2)-15-52TOM
Source Optical Port
51(ODU1LP1/ODU1LP1)
Source Optical Channel (eg.1,3-6)
1
Sink Slot
Shelf2(Subrack2)-15-52TOM
Sink Optical Port
9(RX7/TX7)
Sink Optical Channel (eg.1,3-6)
1
Parameters
Value
Level
OTU1
Service Type
-
Direction
Unidirectional
Source Slot
Shelf2(Subrack2)-15-52TOM
Source Optical Port
51(ODU1LP1/ODU1LP1)
Source Optical Channel (eg.1,3-6)
1
Sink Slot
Shelf2(Subrack2)-15-52TOM
Sink Optical Port
10(RX8/TX8)
Sink Optical Channel (eg.1,3-6)
1
NOTE:
The working channel port and the protection channel port are the two ports for dual feeding. The service in the working channel must be set as bidirectional, and the service in the protection channel must be set as unidirectional. In this
example, port 9 (RX7/TX7) in the working channel port, and port 10 (RX8/TX8) is the protection channel port.
Configure the selective receiving feature for the WDM side of the 52TOM board.
In the NE Explorer, select the NE and choose Configuration > Port Protection.
In the Port Protection user interface, click New. In the Confirm dialog box displayed, click OK. The Create Protection Group dialog box displayed. Select Intra-Board 1+1 Protection from the Protection Type. Enter the other parameters of the protection group. For details of parameters, refer to Feature Description.
Parameters
Value
Protection Type
Intra-Board 1+1 Protection
NE with Working Channel
NE8850
Board with Working Channel
Shelf2(Subrack2)-15-52TOM
Working Channel
9(RX7/TX7)
NE with Protection Channel
NE8850
Board with Protection Channel
Shelf2(Subrack2)-15-52TOM
Protection Channel
10(RX8/TX8)
Click OK. In the window that is displayed, click Close. The created protection group is displayed in the window.