This section considers station A as an example to describe the configuration process of the 52TOM board.
The client-side optical interface cannot be set to Client Side Color Optical Port.
A ClientLP port can access only one service that has a rate higher than 1.25 Gbit/s, and this service can be configured in only the first channel of the ClientLP port.
Services can be input through the eight pairs of client-side optical ports at a maximum rate of 2.5 Gbit/s.
| Parameters | Value |
|---|---|
Level |
ODU1 |
Service Type |
- |
Direction |
Bidirectional |
Source Slot |
Shelf2(Subrack2)-15-52TOM |
Source Optical Port |
201(ClientLP1/ClientLP1) |
Source Optical Channel (eg.1,3-6) |
1 |
Sink Slot |
Shelf2(Subrack2)-12-52NS2 |
Sink Optical Port |
51(ODU1LP/ODU1LP) |
Sink Optical Channel (eg.1,3-6) |
1 |