Configuration Process

This section considers station A as an example to describe the configuration process of the 52TOM board.

Precautions

NOTE:

The client-side optical interface cannot be set to Client Side Color Optical Port.

NOTE:

A ClientLP port can access only one service that has a rate higher than 1.25 Gbit/s, and this service can be configured in only the first channel of the ClientLP port.

NOTE:

Services can be input through the eight pairs of client-side optical ports at a maximum rate of 2.5 Gbit/s.

Procedure

  1. Set the Working Mode of the 52TOM board. In the NE Explorer, select a 52TOM board, and choose Configuration > Working Mode from the Function Tree. Set Board Working mode to Cascading and then set Port Working Mode to ODU1 mode (OTU1/Any->ODU1). For details, see Configuring the Working Mode of the 52TOM Board.
  2. In the NE Explorer, select the desired board , and choose Configuration > WDM Interface from the Function Tree. Configure the Service Type at the WDM Interface of the 52TOM. For details, see Configuring the Service Type.
  3. Configure the cross-connections from the RX/TX ports to the ClientLP ports on the 52TOM board for the Any services of the board.
    1. Configure the cross-connections from the RX/TX ports to the ClientLP ports on the 52TOM board for the Any services that are input to the board.

      NOTE:

      In this scenario, for Any services, only the FE, GE, FC100, FICON, DVB-AS, DVB-SDI, ESCON, and FDDI services can be accessed.

      Parameters Value

      Level

      ANY

      Service Type

      FE

      Direction

      Bidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      3(RX1/TX1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-15-52TOM

      Sink Optical Port

      201(ClientLP1/ClentLP1)

      Sink Optical Channel (eg.1,3-6)

      1

      NOTE:

      The Service Type must be the same as the Service Type at the WDM port of the 52TOM board.

    2. Repeat 3.a to configure the remaining Any services.
  4. Configure electrical cross-connections for the ODU1 services between the 52TOM and 52NS2 boards.

    Parameters Value

    Level

    ODU1

    Service Type

    -

    Direction

    Bidirectional

    Source Slot

    Shelf2(Subrack2)-15-52TOM

    Source Optical Port

    201(ClientLP1/ClientLP1)

    Source Optical Channel (eg.1,3-6)

    1

    Sink Slot

    Shelf2(Subrack2)-12-52NS2

    Sink Optical Port

    51(ODU1LP/ODU1LP)

    Sink Optical Channel (eg.1,3-6)

    1