Configuration Process

This section considers station A as an example to describe the configuration process of the 52TOM board.

Precautions

NOTE:
  • Two channels with the same type of services at the ClientLP1 and ClientLP2 ports respectively must not be used at the same time. For example, if the 201(ClientLP1/ClientLP1)-1 service type is configured, the 202(ClientLP2/ClientLP2)-1 service type must not be configured.
  • The total rate of services that are input through each group of ClientLP ports must not be higher than 1.25 Gbit/s.
  • Only one GE service can be input through each group of ClientLP ports.
  • Services can be input through the six pairs of client-side optical ports at a maximum rate of 2.5 Gbit/s.
  • Services can be input through each client-side optical port at a maximum rate of 1.25 Gbit/s.
  • In cascade mode, only RX7/TX7 and RX8/TX8 can be used as the WDM-side optical interfaces.

Procedure

  1. Set the Working Mode of the 52TOM board. In the NE Explorer, select a 52TOM board, and choose Configuration > Working Mode from the Function Tree. Set Board Working mode to Cascading and then set Port Working Mode to ODU0 tributary-line mode (Any->ODU0->ODU1->OTU1). For details, refer to Configuring the Working Mode of the 52TOM Board.
  2. In the Path Views, Set the type of client-side ports 9 (RX7/TX7) and 10 (RX8/TX8) to Line Side Color Optical Port. For details, refer to Modifying Ports.

    NOTE:

    When the 52TOM board is used as a tributary & line board, the Type of this optical interface must be changed to Line Side Color Optical Port.

  3. Configure the Service Type at the WDM Interface of the 52TOM. For details, refer to Configuring the Service Type.

  4. In the NE Explorer, select the desired board , and choose Configuration > WDM Interface from the Function Tree. Configure the cross-connections from the RX/TX ports to the ClientLP ports on the 52TOM board for the Any services of the board.
    1. Configure the cross-connections from the RX/TX ports to the ClientLP ports on the 52TOM board for the Any services of the board.

      NOTE:

      In this scenario, for Any services, only the FE, GE, FC100, FICON, DVB-AS, DVB-SDI, ESCON, and FDDI services can be accessed.

      Parameters Value

      Level

      ANY

      Service Type

      FE

      Direction

      Bidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      3(RX1/TX1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-15-52TOM

      Sink Optical Port

      201(ClientLP1/ClentLP1)

      Sink Optical Channel (eg.1,3-6)

      1

      NOTE:

      The Service Type must be the same as the Service Type at the WDM interface of the 52TOM board.

    2. Repeat 4.a to configure the remaining Any services.
  5. Configure two separate cross-connections from the internal logical port to ports 9 (RX7/TX7) and 10 (RX8/TX8) for the 52TOM board to achieve dual feeding.
    1. Configure two separate cross-connections from the internal logical port to ports 9 (RX7/TX7) and 10 (RX8/TX8) for the 52TOM board to achieve dual feeding.

      Parameters Value

      Level

      OTU1

      Service Type

      -

      Direction

      Bidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      51(ODU1LP1/ODU1LP1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-15-52TOM

      Sink Optical Port

      9(RX7/TX7)

      Sink Optical Channel (eg.1,3-6)

      1

      Parameters Value

      Level

      OTU1

      Service Type

      -

      Direction

      Unidirectional

      Source Slot

      Shelf2(Subrack2)-15-52TOM

      Source Optical Port

      51(ODU1LP1/ODU1LP1)

      Source Optical Channel (eg.1,3-6)

      1

      Sink Slot

      Shelf2(Subrack2)-15-52TOM

      Sink Optical Port

      10(RX8/TX8)

      Sink Optical Channel (eg.1,3-6)

      1

      NOTE:

      The working channel port and the protection channel port are the two ports for dual feeding. The service in the working channel must be set as bidirectional, and the service in the protection channel must be set as unidirectional. In this example, port 9 (RX7/TX7) in the working channel port, and port 10 (RX8/TX8) is the protection channel port.

  6. Configure the selective receiving feature for the WDM side of the 52TOM board.
    1. In the NE Explorer, select the NE and choose Configuration > Port Protection.
    2. In the Port Protection user interface, click New. In the Confirm dialog box displayed, click OK. The Create Protection Group dialog box displayed. Select Intra-Board 1+1 Protection from the Protection Type. Enter the other parameters of the protection group. For details of parameters, refer to Feature Description.

      Parameters Value

      Protection Type

      Intra-Board 1+1 Protection

      NE with Working Channel

      NE8850

      Board with Working Channel

      Shelf2(Subrack2)-15-52TOM

      Working Channel

      9(RX7/TX7)

      NE with Protection Channel

      NE8850

      Board with Protection Channel

      Shelf2(Subrack2)-15-52TOM

      Protection Channel

      10(RX8/TX8)

    3. Click OK. In the window that is displayed, click Close. The created protection group is displayed in the window.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.