Project Description

This section describes the Ethernet service configuration in a ring network.

See Figure 1. The project is a ring network consisting of four ONEs named A, B, C and D. All ONEs are OADM stations.

Figure 1 Network design diagram for the project

: OADM

In the project, there are three Ethernet services. They are the bidirectional services between ONEs A and B, ONEs A and C, and ONEs A and D. The three services are provided with VLAN SNCP protection. In the receive direction, the east service is the working service and the west service is the protection service.

Two L4G boards are configured in each ONE. Figure 2 gives the unidirectional service allocation. The services to be configured on each ONE are listed in Table 1, Table 2 and Table 3.

Figure 2 Unidirectional electrical cross-connection design of the project

: client-side signals : protection service in the receive direction
: WDM-side working service : working service in the receive direction
: WDM-side protection service : common route for the working and protection services
Table 1 VLAN SNCP services to be configured on each ONE
ONE VLAN SNCP Protection (Working Source & Protection Source > Sink) VLAN ID of Source Port and Sink Port Port Type and Tag Sign (Port Type & Tag Sign)
A 106-11L4G-VCTRUNK1 & 106-11L4G-VCTRUNK2 > 106-11L4G-PORT3 1 UNI&Hybird
106-11L4G-VCTRUNK1 & 106-11L4G-VCTRUNK2 > 106-11L4G-PORT4 2 UNI&Hybird
106-11L4G-VCTRUNK1 & 106-11L4G-VCTRUNK2 > 106-11L4G-PORT5 3 UNI&Hybird
B 106-11L4G-VCTRUNK1 & 106-11L4G-VCTRUNK2 > 106-11L4G-PORT3 1 UNI&Hybird
C 106-11L4G-VCTRUNK1 & 106-11L4G-VCTRUNK2 > 106-11L4G-PORT4 2 UNI&Hybird
D 106-11L4G-VCTRUNK1 & 106-11L4G-VCTRUNK2 > 106-11L4G-PORT5 3 UNI&Hybird
Table 2 Bidirectional EPL services to be configured on each ONE
ONE Source Port Source Port VLAN ID (e.g.1,3-6) Sink Port Sink Port VLAN ID (e.g.1,3-6)
B 106-11L4G-VCTRUNK1 2 106-11L4G-VCTRUNK2 2
106-11L4G-VCTRUNK1 3 106-11L4G-VCTRUNK2 3
C 106-11L4G-VCTRUNK1 1 106-11L4G-VCTRUNK2 1
106-11L4G-VCTRUNK1 3 106-11L4G-VCTRUNK2 3
D 106-11L4G-VCTRUNK1 1 106-11L4G-VCTRUNK2 1
106-11L4G-VCTRUNK1 2 106-11L4G-VCTRUNK2 2
Table 3 Bidirectional electrical cross-connection services to be configured on each ONE
ONE Source Sink
A 106-11L4G-101(AP1/AP1)-1 106-11L4G-201(LP/LP)-1
106-11L4G-102(AP2/AP2)-1 107-11L4G-201(LP/LP)-1
B 106-11L4G-101(AP1/AP1)-1 106-11L4G-201(LP/LP)-1
106-11L4G-102(AP2/AP2)-1 107-11L4G-201(LP/LP)-1
C 106-11L4G-101(AP1/AP1)-1 106-11L4G-201(LP/LP)-1
106-11L4G-102(AP2/AP2)-1 107-11L4G-201(LP/LP)-1
D 106-11L4G-101(AP1/AP1)-1 106-11L4G-201(LP/LP)-1
106-11L4G-102(AP2/AP2)-1 107-11L4G-201(LP/LP)-1

Huawei Proprietary and Confidential