Service Package

The service package module helps you perform typical service configurations. In this manner, you are freed from the field commissioning. This reduces costs of deployment commissioning and maintenance of products. In addition, the equipment can be configured in a one-touch manner.

Service Package Operation Scenario

Service package is a new feature of the OptiX OSN 1800(NA). According to this feature, During deployment, you need to manually select a typical service package for service configuration, and then issue a service package command to configure services and query the service package information.

The system state and mode are as follows:
  • Currently, the expansion cannot be performed based on existing services. If the expansion is required, you need to clear the existing services and then configure new services.
  • When the service of another type needs to be added through any one of optical interfaces 3-6 of the LQM2, re-configure the interface in the common mode; otherwise, the service is not available.
  • If an active/standby switching occurs during the loading of the service package script, you need to upload the script again.
  • If the NE is reset or switched during the configuration of a script, you need to restart the service package.

Service Package Configuration Specifications

The OptiX OSN 1800(NA) support the GE service package and the Hybrid Transmission of the GETH/OC3 Services package. The LQM, LQM2 and LWX2 boards support the service package configuration.

You can also issue a command to manually apply a service package, the service package can be used to automatically configure services of all boards on the NE. The manual application of a service package clears all the previous configuration data on the NE, and then the required configuration commands are executed. Actually, the service package issues a series of configuration commands to configure cross-connections and types of services on ports.

Table 1 describes the configuration of the LQM board.
Table 1 Service configuration on optical ports of the LQM board
 

Optical Port 3

Optical Port 4

Optical Port 5

Optical Port 6

GETH service package

GE

GE

Null

Null

GETH/OC3 service package

GE

GE

OC3

OC3

NOTE:

In the case of the LQM board, the configuration commands issued by the service package do not support any cross-connection.

Table 2 describes the configuration of the LQM2 board.
Table 2 Service configuration on optical ports of the LQM2 board
 

Optical Port 3

Optical Port 4

Optical Port 5

Optical Port 6

Optical Port 7

Optical Port 8

Optical Port 9

Optical Port 10

GETH service package

GE

GE

Null

Null

Null

Null

Null

Null

GETH/OC3 service package

GE

GE

OC3

OC3

Null

Null

Null

Null

NOTE:

In the case of the LQM2 board, the configuration commands issued by the service package can be used to configure straight-through cross-connections on optical ports 3 and 4.

Table 3 describes the configuration of the LWX2 board.
Table 3 Service configuration on optical ports of the LWX2 board
 

Optical Port 5

Optical Port 6

GETH service package

GE

GE

GETH/OC3 service package

GE

GE

NOTE:

In the case of the LWX2 board, the configuration commands issued by the service package do not support any cross-connection.

For details about optical ports in configuration commands issued by the service package, refer to Hardware Description.