Before you configure a PRBS test on the meter board, set PRBS Through of the auxiliary boards at the near and far ends.
The corresponding OTU must be configured.
The service type must be set according to the board type. only support OTN service.
The WDM-side outloop, client-side inloop, or fiber loopback is configured on the remote auxiliary board based on the networking requirements.
In the case of OptiX ONS 3800A/6800A/8800(NA) series, 12NS2, 11ND2, 12TQM, 12LSX, 11LQG, 12LQMS, 12LQMD, 13LQM, 11LOM, 11TOM, 11TQX, 12TDX, 12LSXL, LSQ, 51NQ2, 11LOG, 12ND2, 12LOG, 12LDX, 12ELQX, 12PTQX, 12LOM, 52NS3, 52ND2, 52NS2, 52NQ2, 52TQX, 52TDX, 52TOM, 11LEX4, 11LEM24, 53TSXL, 54ENQ2, 54NPO2, 11LEX4, 11LEM24 boards, only the WDM side supports the PRBS function of sending PRBS signals. In the case of the 12LSX, 11TMX and 12TMX boards, both the client and WDM sides support the PRBS function of sending PRBS signals.
In the case of OptiX ONS 1800(NA) series, LDE, LQPU, LQPL, ELOM, LOE, LOEU, LSX boards, only the WDM side supports the PRBS function of sending PRBS signals.