OAM Error Frame Monitor

In this user interface, you can define the parameters of error frame monitoring.

Navigation Path

In the NE Explorer, select a board and choose Configuration > Ethernet Maintenance > Ethernet Port OAM from the Function Tree. Click the OAM Error Frame Monitor tab.

Parameters

Field

Value

Description

PORT

For example: PORT1

Displays the port name.

Error Frame Monitor Window (ms)

1000 to 60000

Increment: 100

In the specific Error Frame Monitor Window (ms), if the number of the error frames on the link exceeds the value of the Error Frame Monitor Threshold (Entries), a performance event is reported.

Error Frame Monitor Threshold (Entries)

For example: 10

Sets the monitoring threshold of the error frame.

Error Frame Period Window (frames)

1488 to 892800000

In the specific Error Frame Period Window (frames), if the number of the error frames on the link exceeds the value of the Error Frame Period Threshold (frames), a performance event is reported.

Error Frame Period Threshold (frames)

1 to 892800000

Sets the monitoring threshold of the error frame period.

Error Frame Second Window (s)

10 to 900

If an error frame occurs within a second, this second is the error frame second.

In the specific Error Frame Second Window (s), if the number of the error frame seconds on the link exceeds the value of the Error Frame Second Threshold (s), a performance event is reported.

Error Frame Second Threshold (s)

1 to 900

Sets the monitoring threshold of the error frame second.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.