In this user interface, you can query or set basic attributes of an internal port, including port and QinQ type area.
In the NE Explorer, click the board and select . Click the Internal Port and then click Basic Attributes tab.
Button |
Description |
|
|---|---|---|
State |
IS |
Sets the state of the port to be in service. |
OOS |
Sets the state of the port to be out of service. |
|
Maintenance |
Remove |
Changes the service state of the specified port to Out of Service - Maintenance (OOS-MA, MT). After the remove action, there is no alarm generated for the corresponding facility and existing alarms must be cleared. Any circumstances are reported as not required (NR) and performance message (PM) continues to be collected and is marked invalid. This is done before performing loopback. |
Restore |
Instructs an NE to restore service of the port on the card. The card will change the port state from maintenance to the original state. All existing alarms must be reported. |
|
Field |
Value |
Description |
|---|---|---|
Port |
VCTRUNKn, RPRn |
VCTRUNK and RPR are the ports, and n indicates the port number. |
QinQ Type Area |
0x0600 to 0xFFFF |
Displays in hexadecimals. |
Primary, Secondary State |
For example: IS-NR |
Displays the state of the port. |
Signal Validation Timer |
Format:00-03 |
Signal validation timer in minutes. It is valid only when Auto In-Service feature is supported. It is a string, and the format is HH-MM. |