In this user interface, you can set and query the dispersion compensation value, set and query the enabling status of fine adjusting dispersion compensation, enable or disable the best dispersion compensation search, and query the searching status of the best value.
In the NE Explorer, select a board and choose from the Function Tree.
Button |
Description |
|
|---|---|---|
Start Scan |
Starts the scan for the best dispersion compensation value. |
|
Stop Scan |
Stops the scan for the best dispersion compensation value. |
|
State |
IS |
Sets the state of the TDC to be in service. |
OOS |
Sets the state of TDC to be out of service. |
|
ANIS |
Sets the state of TDC to be in service automatically. |
|
Field |
Value |
Description |
|---|---|---|
Optical interface |
|
Displays the board port of dispersion compensation. |
Auto Adjust |
ENABLE, DISABLE |
Indicates whether dispersion fine adjustment is enabled. |
TDC State |
IDLE, SUCCESS, FAIL, ADJUSTING |
Indicates the current state of dispersion adjustment. |
TDC Value (ps/nm) |
-400 to 400 |
Displays the best dispersion compensation queried from the NE after successful search or the dispersion compensation value that you set. |
TDC Min (ps/nm) |
For example: -32768 |
Displays the minimum dispersion compensation queried from the NE. |
TDC Max (ps/nm) |
For example: 32767 |
Displays the maximum dispersion compensation queried from the NE. |
TDC Step (ps/nm) |
-32768 to 32767 |
Displays the adjustment step adopted by the dispersion compensation modules. |
Signal Validation Timer |
For example: 00-03 |
Sets the signal validation timer in minutes. NOTE:
It is a string, and the format is HH-MM. |
Primary, Secondary State |
For example: OOS-AU, SGEO |
Displays the state of the port. |