Spectrum Analysis Unit

The spectrum analysis unit provides the built-in in-service spectrum analysis and monitoring functions for the system. It can, with the service not interrupted, monitor such parameters as central wavelength, power and signal-to-noise of the optical signal in the system and report the result to the SCC unit and the network management system for the convenience of equipment debugging and maintenance. After being installed, the spectrum analyzer unit needs to be configured through this interface.

In this user interface, you can set the monitor interval of the spectrum analysis unit.

Navigation Path

In the NE Explorer, select an MCA card and select Configuration > WDM Interface from the Function Tree.

Buttons

Button

Description

By Card/Channel

Lists port parameters of all selected NEs and cards.

By Function

Lists a selected port parameter of all selected NEs and cards.

Power Saving

SB

Start power saving function of the channel.

NOTE:
The state of power saving can not be set as SB when the channel is in the Remove state.

SB-DEA

Cancel power saving function of the channel.

Maintenance

Remove

Changes the service state of the specified port to Out of Service - Maintenance (OOS-MA, MT).

After the remove action, there is no alarm generated for the corresponding facility and existing alarms must be cleared. Any circumstances are reported as not required (NR) and performance message (PM) continues to be collected and is marked invalid. This is done before performing loopback and NULL mapping status.

Restore

Instructs an NE to restore service of the port on the card. The card will change the port state from maintenance to the original state. All existing alarms must be reported.

State

IS

Sets the state of the ports to be in service.

OOS

Sets the state of the ports to be out of service.

AINS

Sets the state of the ports to be automatic in service.

Parameters

Field

Value

Description

Optical Interface

  • Equipment that supports the master and slave shelf management: NE name-shelf ID(shelf name)-slot number-board name-port number(port name)-monitoring level
  • Equipment that does not support the master and slave shelf management: NE name-slot number-board name-port number(port name)-monitoring level

Displays the current optical port/path location.

Primary, Secondary State

OOS-AUMA,UEQ&UAS; OOS-MA,UAS; OOS-AU,UEQ; OOS-AUMA,UEQ; OOS-AU,AINS&UEQ; OOS-AU,MEA; OOS-AUMA,MEA; OOS-AU,AINS&MEA; OOS-AU,FLT; OOS-AUMA,FLT; OOS-AU,AINS&FLT; OOS-MA; IS-NR; IS-NR,SWDL; OOS-MA,SWDL

Displays the state of the slot.

OOS-AUMA,UEQ&UAS: The card is not created and in position.

OOS-MA,UAS: The card is not created but is in position.

OOS-AU,UEQ: The card is in the IS state but not in position.

OOS-AUMA,UEQ: The card is in OOS state but not in position.

OOS-AU,AINS&UEQ: The card is in AINS state but not in position.

OOS-AU,MEA: The card is in the IS state and in position. But the logic type of the card and its physical type mismatch.

OOS-AUMA,MEA: The card is in the OOS state and in position. But the logic type of the card and its physical type mismatch.

OOS-AU,AINS&MEA: The card is in the AINS state and in position. But the logic type of the card and its physical type mismatch.

OOS-AU,FLT: The card is in the IS state and in position. But the card fails.

OOS-AUMA,FLT: The card is in the OOS state and in position. But the card fails.

OOS-AU,AINS&FLT: The card is in the AINS state and in position. But the card fails.

OOS-MA: The card is in the IS state and in position. But it is changed to the OOS state manually.

IS-NR: The card is in the IS state and in position. No card failure.

IS-NR,SWDL: The card is in the IS state and in position. Software is being loaded.

OOS-MA,SWDL: The card is in the IS state and in position. But it is changed to the OOS state manually. Software is being loaded.

Port Name

For example: IN1

Displays Port Name.

Port Remarks

Character string

Sets the remarks for the port.

Provision Working Band Type

C-ALL, C-ODD, C-EVEN

Displays the parity of the current working band of the port.

Actual Work Band

C-ALL, C-ODD, C-EVEN

Displays the actual work band.

Signal Validation Timer

00-03 to 48-00

Sets the signal validation time of the optical port.

Port

  • Equipment that supports the master and slave shelf management: NE name-shelf ID(shelf name)-slot number-board name-port number(port name)-channel number
  • Equipment that does not support the master and slave shelf management: NE name-slot number-board name-port number(port name)-channel number

Displays the port to be set.

Wavelength Monitor Enable Flag

Y, N

Displays whether the wavelength is monitored.

Band

For example: CBAND

Displays the band.

Card

  • Equipment that supports the master and slave shelf management: NE name-shelf ID(shelf name)-slot number-board name
  • Equipment that does not support the master and slave shelf management: NE name-slot number-board name

Displays the card.

MCASCANSPAN

5 to 49995

Sets the time interval of wavelength data collection. The value must be a multiple of 5.

MCAMONTYPE

NRZDRZ, 100GCRZ,50GCRZ, 100G40G, 50G40G

Sets the monitoring type for the card.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.