Optical Amplifier Unit

The optical amplifier unit amplifies and equalize the optical power, greatly enhancing the transmission distance of the radio relay and the signal-to-noise of the optical signal. After being installed, the optical booster amplifier unit need to be configured through this interface.

In this user interface, you can provision the optical amplifier unit, including the following operations.
  • Changing the primary state and secondary state.
  • Querying the threshold power of lost of signal, work band and current gain.
  • Setting the attenuation rate.

Navigation Path

In the NE Explorer, select a board and select Configuration > WDM Interface from the Function Tree.

Buttons

Button

Description

By Card/Channel

Lists port parameters of all selected NEs and cards.

By Function

Lists a selected port parameter of all selected NEs and cards.

Power Saving

SB

Start power saving function of the channel.

NOTE:
The state of power saving can not be set as SB when the channel is in the Remove state.

SB-DEA

Cancel power saving function of the channel.

Maintenance

Remove

Changes the service state of the specified port to Out of Service - Maintenance (OOS-MA, MT).

After the remove action, there is no alarm generated for the corresponding facility and existing alarms must be cleared. Any circumstances are reported as not required (NR) and performance message (PM) continues to be collected and is marked invalid. This is done before performing loopback and NULL mapping status.

Restore

Instructs an NE to restore service of the port on the card. The card will change the port state from maintenance to the original state. All existing alarms must be reported.

State

IS

Sets the state of the ports to be in service.

OOS

Sets the state of the ports to be out of service.

AINS

Sets the state of the ports to be automatic in service.

Parameters

Field

Value

Description

Optical Interface

  • Equipment that supports the master and slave shelf management: NE name-shelf ID(shelf name)-slot number-board name-port number(port name)-monitoring level
  • Equipment that does not support the master and slave shelf management: NE name-slot number-board name-port number(port name)-monitoring level

Displays Optical interface Name.

Primary, Secondary State

OOS-AUMA,UEQ&UAS; OOS-MA,UAS; OOS-AU,UEQ; OOS-AUMA,UEQ; OOS-AU,AINS&UEQ; OOS-AU,MEA; OOS-AUMA,MEA; OOS-AU,AINS&MEA; OOS-AU,FLT; OOS-AUMA,FLT; OOS-AU,AINS&FLT; OOS-MA; IS-NR; IS-NR,SWDL; OOS-MA,SWDL

Displays the state of the slot.

OOS-AUMA,UEQ&UAS: The card is not created and in position.

OOS-MA,UAS: The card is not created but is in position.

OOS-AU,UEQ: The card is in the IS state but not in position.

OOS-AUMA,UEQ: The card is in OOS state but not in position.

OOS-AU,AINS&UEQ: The card is in AINS state but not in position.

OOS-AU,MEA: The card is in the IS state and in position. But the logic type of the card and its physical type mismatch.

OOS-AUMA,MEA: The card is in the OOS state and in position. But the logic type of the card and its physical type mismatch.

OOS-AU,AINS&MEA: The card is in the AINS state and in position. But the logic type of the card and its physical type mismatch.

OOS-AU,FLT: The card is in the IS state and in position. But the card fails.

OOS-AUMA,FLT: The card is in the OOS state and in position. But the card fails.

OOS-AU,AINS&FLT: The card is in the AINS state and in position. But the card fails.

OOS-MA: The card is in the IS state and in position. But it is changed to the OOS state manually.

IS-NR: The card is in the IS state and in position. No card failure.

IS-NR,SWDL: The card is in the IS state and in position. Software is being loaded.

OOS-MA,SWDL: The card is in the IS state and in position. But it is changed to the OOS state manually. Software is being loaded.

Signal Validation Timer

  • OSN OptiX 1800(NA): 00-01 to 48-00
  • OSN OptiX 3800A/6800A/8800 T16(NA)/8800 T32(NA)/8800 T64(NA): 00-03 to 48-00

Sets the signal validation time of the optical port.

Port Name

For Example: IN

Displays Port Name.

Laser Status

OPEN, CLOSE

Displays whether the laser is open.

Actual Gain

An integer number

Displays the actual gain of the board.

Standard Gain

0 to 40.0

Sets the standard gain of the board.

Max Gain Threshold (dB)

For example: 35

Displays the upper threshold of the gain of the optical amplifier board.

Min Gain Threshold (dB)

For example: 15

Displays the lower threshold of the gain of the optical amplifier board.

Provision Working Band Type

C-EVEN, C-ODD, C-ALL

Displays the parity of the current working band of the port.

Actual Work Band

For example: CBAND

Displays the actual working band of the optical amplifier board.

Loss Laser Threshold

For example: -35.0

Displays the loss laser threshold.

Related Optical Power (dBm)

-30 to 30

Sets the related optical power.

DEG Threshold

0 to 10167

Indicates the signal degradation threshold when bit errors are distributed in the BURST mode.

Launch Power(dBm)

-60.0 to 60.0

Sets the launch power of the optical port.

The Upper Threshold of RL to starting the pump (dBm)

-

Queries the upper threshold of RL to starting the pump.

The Lower Threshold of RL to starting the pump (dBm)

-

Queries the lower threshold of RL to starting the pump.

The Lower Threshold of RL alarm (dBm)

-

Queries the lower threshold of RL alarm.

Enable the RL check

ENABLE, DISABLE

Enables or disables RL flag.

DEG Monitoring Time(s)

2 to 10

Indicates the DEG detection time.

Degrade Threshold Before FEC

1E-1 to 1E-12

Default: 1E-6

Indicates the threshold of the signal degraded before FEC.


Huawei Proprietary and Confidential