In this user interface, you can create normal electrical cross-connections and SNCP services. You can also perform conversion between these two types of services. If the created service is not properly configured during configuration, the U2000 Web LCT does not send the new service data to NEs and it automatically notifies the operator.
In the NE Explorer, click an NE and choose from the Function Tree. Click the Electrical Cross-Connection Configuration tab.
Button |
Description |
|---|---|
Query |
Queries configured services of the NE and the service status from the NE. |
New |
Creates an electrical cross-connection. |
Create SNCP |
Creates an SNCP protection group. |
Delete |
Deletes services. |
Convert to Non-Protection Service |
Converts the working services in the SNCP protection group to a non-protection service. |
Convert to SNCP Service |
Converts a non-protection service to an SNCP service. |
Select All |
Selects all of the cross-connections in the cross-connection list. |
Unfold |
Displays only a single cross-connection. |
Field |
Value |
Description |
|---|---|---|
Service Level |
GE, Any, OTU1, OTU2, OTU3, ODU0, ODU1, ODU2, ODU3, ODU5G |
Specifies the level of the new service. |
Direction |
Bidirectional, Unidirectional |
If the receive service and transmit service have the same route, they are regarded as a bidirectional service. If the receive service and transmit service have different routes, they are two unidirectional services. |
Service Type |
For GE, OTUK and ODUk services, this value cannot be modified. For Any services, FE, FC50, STM-1, STM-4, STM-16, OC3, OC12, OC48, FC100, FC200, FICON, FICON Express, HDSDI, DVBASI, SDI, ESCON, FDDI, IBSDR, IBDDR |
Specifies the type of the new service. |
Occupied ODTUk Timeslots |
1 to 8 |
Indicates the quantity of ODUflex timeslots.
NOTE:
Recommended value for Occupied ODTUk Timeslots:
|
Service Rate(bit/s) |
1 to 9993964557 |
Indicates or sets the service rate.
NOTE:
Set this parameter when Level of a WDM cross-connection is ODUflex and Service Type is Custom. |
Source Slot |
|
Displays the source slot of the service. |
Source Port |
For example: 1(LP/LP) |
Displays the source port of the service. |
Source Optical Path (e.g. 1,3-6) |
For example: 3-1 |
Displays the source optical path of the service. |
Sink Slot |
|
Displays the sink slot of the service. |
Sink Port |
For example: 201(AP1/AP1) |
Displays the sink port of the service. |
Sink Optical Path (e.g. 1,3-6) |
For example: 3-1 |
Displays the sink optical path of the service. |
Remarks |
The maximum length is 32 characters. |
Displays the remarks for the service. |
Field |
Value |
Description |
|---|---|---|
Protection Type |
SW SNCP, ODUk SNCP |
Specifies the level of the new service. |
Direction |
Bidirectional, Unidirectional |
If the receive service and transmit service have the same route, they are regarded as a bidirectional service. If the receive service and transmit service have different routes, they are two unidirectional services. |
OTN level |
For SNC/N: PM, TCM1, TCM2, TCM3, TCM4, TCM5, TCM6 For SNC/S: TCM1, TCM2, TCM3, TCM4, TCM5, TCM6 |
Sets the OTN level of the service. |
SNCP Type |
|
Displays the protection type of the service. |
Service Type |
|
Specifies the service type of the new service. |
Revertive Mode |
Revertive, Non-Revertive |
Chooses whether the service is switched to the original working path after the failure is eliminated. If you want the service to be switched back to the original working path then, select Revertive. If you do not want the service to be switched back then, select Non-Revertive. |
WTR Time (mm:ss) |
5:00-12:00 |
Sets the wait-to-restore time. It is the time interval between the time when the working service is detected to be normal after switching and the time when the service is switched back to the working path. You can modify the Revertive Mode only when the value is Revertive. |
Protection Channel Hold-Off Time (100ms) |
0-100 |
Sets the time interval between the time when the system detects signal degrade and the time when the service switching occurs, in order to avoid repeated switching when the service status is not stable. The Protection Channel Hold-Off Time (100ms) is the switching delay time for protection channel. |
Working Channel Hold-Off Time (100ms) |
0-100 |
Sets the time interval between the time when the system detects signal degrade and the time when the service switching occurs, in order to avoid repeated switching when the service status is not stable. The Working Channel Hold-Off Time (100ms) is the switching delay time for working channel. |
SD Enabling Flag |
Enabled, Disabled |
Sets the SD enabling flag. |
ODUflex Service Type |
For example: FC400 |
Indicate the service type of the configured port.
NOTE:
Set this parameter when Service Type of a WDM cross-connection is ODUflex. |
Occupied ODTUk Timeslots |
1 to 8 |
Indicates the quantity of ODUflex timeslots.
NOTE:
Recommended value for Occupied ODTUk Timeslots:
|
Service Rate(bit/s) |
1 to 9993964557 |
Indicates or sets the service rate.
NOTE:
Set this parameter when Level of a WDM cross-connection is ODUflex and Service Type is Custom. |
Source Slot |
|
Displays the source slot of the cross-connection. |
Source Port |
Port No. (Port name) |
Displays the source port of the cross-connection. |
Source Path (e.g.1,3-6) |
Slot-Optical port No.-Optical path No. |
Displays the source path of the cross-connection. |
Sink Slot |
|
Displays the sink slot of the cross-connection. |
Sink Port |
Port No. (Port name) |
Displays the sink port of the cross-connection. |
Sink Path (e.g.1,3-6) |
Slot-Optical port No.-Optical path No. |
Displays the sink path of the cross-connection. |