NE Attribute

In this user interface, you can view and set NE attributes, including shelf type, and IP address.

Navigation Path

In the NE Explorer, select an NE and choose Configuration > NE Attribute from the Function Tree.

Parameters

Field

Value

Description

Type

For example: OptiX OSN 8800T 32(NA)

Displays the type of an NE.

Name

For example: NE70

Displays the NE name, for the convenience of searching for the NE.

Location

 

Displays the location information of the NE.

Remarks

 

Enters extra notes of the NE if desired.

Shelf Type

For example: NASHELF

Displays the shelf type of an NE.

Gateway Type

IP Gateway

The gateway type of an NE decides the mode of communication between the NE and the NMS.

Gateway IP Address

For example: 10.71.227.149

Displays the IP of the gateway NE.

Gateway Port

3081

Displays the port P of the gateway NE.

IP Address

For example: 192.168.0.1

Displays the IP of the NE.

Port

Default: 3081

Displays the port of the gateway NE.

Daily Monitoring Start Time

For example: 00:00AM

Configures the start time of 24-hour performance monitoring.

Time Zone

For example: UTC

Displays the time zone of the NE.

Daylight Saving Time

Checked, Unchecked

Indicates whether to use daylight saving time.

Auto-Card Installation

Checked, Unchecked

Controls the NE to auto identify whether a board is inserted.

ARP Proxy Enable

Checked, Unchecked

Displays whether the ARP Proxy is enable.

LAN Port Access Control Enable

Checked, Unchecked

Displays whether the LAN Port Access Control is enable.

MAC Address

For example: 08-00-3e-47-e3-70

Displays the MAC Address of an NE.

Subnet Mask

For example: 255.255.254.0

Displays the Subnet Mask of an NE.

Gateway

For example: 129.9.0.1

Sets the IP address of the gateway NE.

Occurring Delay Time (s)

0 to 6

Indicates the duration for the alarm monitoring to persist before the NE reports a newly raised alarm.

Cleaning Delay Time (s)

0 to 20

Indicates the duration for the alarm monitoring to persist before the NE reports that the alarm is cleared.

State Mode Level

Full, Complex

Sets the level of the state mode on the NE.

Buzzer

YES or NOT

Sets to enable or disable the buzzer on the NE.

Country Code

For example: CHN

Selects to set the country code and national segment code.

National Segment Code

For example: 156

Displays the national segment code.

Serial Port Baud Rate (bps)

1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200

Sets the baud rate of the serial port.

Serial Port Link Type

TL1, MML, NM

Sets the link type of the serial port.

Serial port Enable

Checked, Unchecked

Sets whether the serial port is enable.

Auto Release Loopback

YES or NOT

Sets whether start the auto release loopback function.

Auto Release Loopback Time

For example: 00:05

Sets the auto release loopback time.

Power Saving

Nomal, Saving

Sets whether start the NE power saving function.

Outdoor cabinet type

NULL, APM30 AC, APM30 DC, OMB AC , OMB DC

Set the type of outdoor cabinet.

NE Software Version(VRC)

For example: V100R005C00SPC700

Displays the software version of the NE.

  • V: Version
  • R: Release
  • C: Customization

Created By

Character string

Displays the name of the person who creates the NE.

Created On

For example: 10/12/2012 14:18:13

Displays the time when the NE is created.


Huawei Proprietary and Confidential