You can perform performance detection, to check if a link between two nodes is normal.
Prerequisites
The source and sink MEPs, and MIPs in the same maintenance domain must be created.
Background Information
- The source maintenance point that initiates a performance test must be an MEP. The sink maintenance point that responds to the performance test can be an MEP or MIP.
- Performing performance detection does not affect the service.
Procedure
- In the NE Explorer, select an Ethernet board and choose from the Function Tree.
- Optional: Click Query to query OAM information from the NE.
- Select a node, click OAM Operation and select Performance Detect. The Performance Detect window is displayed.

- Set Send Mode.
- Burst Mode, you need to set Packet Length, Timeout, and Detect Attempts.
- If you select Continue Mode, you need to set Packet Length, and Timeout.
- In the Maintenance Point area, set Source MP ID and Destination MP ID.
- Click Start Detect and view the returned result in the Detail pane.
Copyright © Huawei Technologies Co., Ltd.