Configuring a Ping Test

In the ping test, ARP and ICMP Layer 3 protocol packets are used to test the connectivity, packet loss rate and delay time between Ethernet service processing boards and data communication equipment (such as the switch or router).

Prerequisites

  • The OAM maintenance node of a service must be created for an Ethernet board. The type of the maintenance node is MEP.
  • The MEP where the ping test is initiated must be created on an external physical port.
  • The tag attribute of the external physical port where the MEP resides must be Access.

Background Information

  • The ping test can be initiated only from the Ethernet service processing board to the interconnected data communication equipment.
  • The ping test is performed in the direction from the board to which the MEP belongs to the interconnected data communication equipment of the board.
  • A legal IP address is allocated to the MEP, and the IP addresses of the MEP and the interconnected data communication equipment must be in the same network segment.
  • Performing a ping test does not affect the service.

Procedure

  1. In the NE Explorer, select an Ethernet board and choose Configuration > Ethernet Maintenance > Ethernet Service OAM from the Function Tree.
  2. Optional: Click Query to query OAM information from the NE.
  3. Select a node, click OAM Operation and select Start Ping. The Ping Test window is displayed.

  4. Set Send Mode.

    • Burst Mode, you need to set Packet Length, Timeout, and Ping Attempts.
    • If you select Continue Mode, you need to set Packet Length, and Timeout.

  5. In the IP Address Configuration area, set Destination IP Address and Local IP Address.
  6. Click Start Ping and view the returned result in the Detail pane.