You can perform a link trace (LT) check on Ethernet services to check the MIP information in the link for locating and handling faults.
Prerequisites
The source and sink MEPs, and MIPs in the same maintenance domain must be created.
Only MEPs can initiate the LT test and work as the termination point in the test.
The Ethernet board must be created.
Background Information
During the LT check, the source MEP constructs and transmits LTM frames and starts the timer. All the MPs that receive the LTM frames send the LTR frame response. According to the LTR frame response, you can verify all the MIPs that pass from the
source MEP to the destination MEP.
Performing an LT check does not affect the service.
Procedure
In the NE Explorer, select an Ethernet board and choose Configuration > Ethernet Maintenance > Ethernet Service OAM from the Function Tree.
Select the node that you want to monitor, click OAM Operation and select Start LT. The LT Test dialog box is displayed.
Enter the LT test source maintenance point ID and sink maintenance point ID.
NOTE:
Before you perform the check, set an appropriate LT Timeout (ms) as required.