By using the U2000 Web LCT, you can perform or clear protection switching for a board. During deployment and commissioning, you can perform switching to test whether the board protection
switching works properly. In fault maintenance, you can perform this operation to locate faults.
Prerequisites
- The 1+1 board protection group must be available.
- The protection board works properly.
Context
NOTICE: If the protection board is abnormal, services may be interrupted when you perform switching.
Procedure
- In the NE Explorer, select the NE and choose from the Function Tree.
- Click Query to view the active board and the current working board.
- Select a 1+1 protection group and click Working/Protection Switching.
- In the Confirm dialog box that is displayed for two times, click OK and then click Close in the Operation Result dialog box.
- Click Query to refresh the switching status of the 1+1 protection group.
NOTE: In the case of SCC protection pair, you can query standby status of the SCC board.
- Optional: Click Restore Working/Protection to restore the 1+1 protection group to the status before the switching is performed.