On the U2000 Web LCT, each optical interface on the NPO2E board has a serial number, and the logical ports of the board are provided.
Table 1 lists the serial numbers of the optical interfaces on the front panel of the board displayed on the NMS.
| Interface on the Front Panel | Interface on the NMS |
|---|---|
| IN/OUT | 1 |
The number of an interface displayed on the U2000 Web LCT indicates a pair of physical optical interfaces, of which one is used to transmit signals and the other is used to receive signals.
ODU0, ODU1, ODU2, and ODU2e signals carried over the NPO2E board's OCH9 to OCH12 channels are processed on the TN54ENQ2 board.
The OCH9 to OCH12 optical channels only receive the signals coming from the TN54ENQ2 board.
If an ODUk channel has been used, cross-connections cannot be configured on any other channels that correspond to the ODUk channel, regardless of the rate level. For example, if channel 1(IN/OUT)-OCH:1-ODU2:1-ODU1:1 has been used, cross-connections cannot be configured on channel 1(IN/OUT)-OCH:1-ODU2:1 or 1(IN/OUT)-OCH:1-ODU2:1-ODU1:1-ODU0:1.
The NPO2E board's OCH5 to OCH8 optical channels are available only when the board works with the TN54PQ2 service processing board.
![]() |
Cross-connect module | ![]() |
ODU1 mapping path |
![]() |
Multiplexing module | ![]() |
ODU2 mapping path |
![]() |
Service processing module | ![]() |
Cross-connection that must be configured on the NMS to receive ODUk signals from other boards |
![]() |
ODU0 mapping path |
| Port Name | Meaning |
|---|---|
| 1(IN/OUT)-OCH:(1-12)-ODU2:(1-12)-ODU1:(1-4)-ODU0:(1-2) | Indicates the mapping path for the ODU0 signals that are received through the backplane. |
| 1(IN/OUT):(1-12)-ODU2:(1-12)-ODU1:(1-4) | Indicates the mapping path for the ODU1 signals that are received through the backplane. |
| 1(IN/OUT):(1-12)-ODU2:(1-12) | Indicates the mapping path for the ODU2/ODU2E signals that are received through the backplane. |
| 1(IN/OUT) | Indicates the WDM-side port. |
shows configuration of cross-connections from other boards to the NPO2E board. The configuration enables add/drop of client-side services on the line at the local site.
shows configuration of cross-connections from other boards to the NPO2E board. The configuration enables line-side services to pass through the local site.Cross-connections can be configured between the boards working in standard mode and the boards working in compatible mode.

| Other board a | TN52TOG/TN52TOM/TN54THA/TN54TOA |
| Other board b | TN52ND2/TN53ND2/TN52NQ2/TN54NQ2/TN53NQ2/TN53NS2/TN52NS2/TN52NS3/TN54NS3/TN55NPO2/TN54ENQ2 |
| Other board c | TN53NS2/TN53ND2/TN53NQ2/TN55NPO2/TN55NPO2E/TN54ENQ2 |

| Other board a | TN52TOG/TN52TOM/TN54THA/TN54TOA |
| Other board b | TN52ND2/TN53ND2/TN53NQ2/TN52NQ2/TN54NQ2/TN53NS2/TN52NS2 /TN52NS3/TN54NS3/TN55NPO2/TN54ENQ2 |
| Other board c | TN53NS2/TN53ND2/TN53NQ2/TN55NPO2/TN55NPO2E/TN54ENQ2 |