In this user interface, you set the function of inserting the TU_AIS alarm upon the E1_AIS alarm. A hybrid SNCP network can be implemented only after you enable this function.
In the NE Explorer, click the board and select from the Function Tree.
Field |
Value |
Description |
|---|---|---|
Port |
For example: NE6101-2-IFU2-1 |
Indicates the card and port where the triggered alarm insertion is enabled. |
High Channel |
For example: VC4-1 |
Indicates the higher order path where the triggered alarm insertion is enabled. |
Low Channel |
For example: 1 |
Indicates the lower order path where the triggered alarm insertion is enabled. |
Insert E1_AIS to TU_AIS |
Auto, Enabled, Disabled |
Sets the status of the triggered alarm insertion.
NOTE:
When Insert E1_AIS to TU_AIS is Auto, the E1_AIS is automatically inserted after the TU_AIS is detected in the E1 channel. Generally, it is recommended that Auto take its default value. |