In this interface, you can query and set the advanced attributes of the PDH interface.
As a loopback interrupts services, it is only used for fault location and must be released after the fault is removed.
Field |
Value |
Description |
|---|---|---|
Port |
For example: Slot-Board Name-Port (Port No.) |
Display the port name. |
Frame Format |
Unframe, Double Frame, CRC-4 Multiframe |
Select the frame format. When the emulation mode of a CES service is CESoPSN, the frame format at the interface should be set to CRC-4 Multiframe. When the emulation mode of a CES service is SAToP, the frame format at the interface should be set to Unframe. |
Line Encoding Format |
HDB3 |
Display the line encoding format. |
Clock Mode |
Master Mode, Slave Mode, Line Clock Mode |
Select the clock mode.
|
Loopback Mode |
Non-Loopback, Inloop, Outloop |
Set the loopback status of the port. |
Composite Port Loopback |
Non-Loopback, Inloop, Outloop Default: Non-Loopback |
|
Impedance |
75 ohm, 120 ohm |
Display the impedance of the interface. |
Service Load Indication |
Load, Non-Loaded Default: Load |
Sets the service loading status of the corresponding port on the tributary board. Object: port To mask all the alarms of a port not loaded with any service on the tributary board, you need to set the service loading indication of this tributary board port to: Non-Loaded. For a tributary board with service running, the corresponding port must be set to: Load. NOTE:
If a path is configured with services and carries real services, set Service Load Indication to Load. If a path is configured with services but does not carry real services, set Service Load Indication to Non-Loaded to suppress the reporting of certain alarms. If you select Non-Loaded, you do not need to click OK in the Confirm dialog box. NOTICE:
If you set the service load indication to Non-Loaded, the services may be interrupted or you may fail to log in to certain NEs. |
Frame Mode |
30, 31 |
Set the value of the frame mode. The frame modes of the local port and opposite port should be the same. NOTE:
|
CES Encapsulation Clock Mode |
-, NULL, Line Clock Mode, System Clock Mode |
Sets the encapsulation mode of the clock signal at the UNI port on the master side of the CES service.
|
CES Encapsulation Clock Poke |
-, Disabled, Enabled |
Configure an E1 port to generate a time stamp on the master NE. NOTE:
When CES ACR is in line clock timestamp mode, the master NE must enable an E1 to generate a time stamp. At the same time, only one E1 port can be enabled on one NE. When one E1 port is enabled to generate a time stamp, if you enable another E1 port, an error message indicating a parameter error will be displayed. |
Select Board |
Example:3-MD1 |
Select the board. |
Idle Timeslot Recovery Value |
-, 0 to 255 |
Set the value of Idle Timeslot Recovery Value |
Input Signal Equalization |
Equalized, Unequalized |
Sets whether the input signals of each port on the tributary board need to be equalized, and whether to select Equalized or Unequalized depends on the cable length. When the selected cable is longer than 70 meters, please select the Equalized mode for this port. |
Output Signal Equalization |
Equalized, Unequalized |
Sets whether the output signals of each port on the tributary board need to be equalized, and whether to select Equalized or Unequalized depends on the cable length. When the selected cable is longer than 70 meters, please select the Equalized mode for this port. |