Ethernet Test

This user interface is for commissioning of installed Ethernet boards and fault location. You can set the send mode, send direction and the number of test frames to be sent.

Navigation Path

In the NE Explorer, select a board and choose Configuration > Ethernet Maintenance > Ethernet Test from the Function Tree.

Buttons

Button

Description

Clear Counters

Clears the Counters of Test Frame.

Clear Counters contain Clear All Counters, Clear Sending Counter, Clear Response Counter and Clear Receiving Counter.

Parameters

Table 1 Ethernet test (Ethernet data board)

Field

Value

Description

Port

  • Equipment that supports the master and slave shelf management: shelf ID(shelf name)-slot number-board name-port number(port name)
  • Equipment that does not support the master and slave shelf management: slot number-board name-port number(port name)

Displays the internal port name.

Send Mode Disabled, Burst Mode, Continue Mode

Default:Disabled

Send Mode(Ethernet Test) is used to set the test frame and the transmit mode of the test frame. The test frame is used for simulating packet transmission to check whether the link is normal.
Send Direction   Send Direction (Ethernet Test) indicates the transmit direction of the test packet.
Frames to Send 1 to 255

Default:1

Frames to Send indicates the number of test packets to be transmitted. With this parameter enabled, the system transmits a test packet every one second until the number of transmitted test packets reaches the specified value.
NOTE:
The number of Frames to Send could be slightly different for some equipment.
Status Sending, Finished Sending

Default:-

Status indicates the transmit status of the current test frames at the port. This parameter is displayed as the current test status after you configure Send Mode and Frames to Send and then click Apply.

Bearer Mode

GFP, Ethernet

Sets the bearer mode of the Ethernet test frame at the local end. The bearer modes at the two ends of the Ethernet test must be consistent.

Remote Bearer Mode

GFP, Ethernet

Displays the bearer mode at the opposite end.

Sent Frame Count

For example: 1

Sent Frame Count indicates the number of test frames that are transmitted by the VC trunk port in the Ethernet test. This parameter value is accumulative. The value indicates the total number of test frames that are transmitted from last time when the parameter value is cleared to this time when the value is queried.
Received Response Test Frame Count

For example: 1

Received Response Test Frame Count indicates the number of response test frames that are received by the VC trunk port in the Ethernet test. This parameter value is accumulative. The value indicates the total number of response test frames that are received from last time when the parameter value is cleared to this time when the value is queried.
Test Frames to Receive

For example: 1

Test Frames to Receive indicates the number of test frames that are received by the VC trunk port in the Ethernet test. This parameter value is accumulative. The value indicates the total number of test frames that are transmitted from last time when the parameter value is cleared to this time when the value is queried.

Enabling Status of Responding Peer Test Frame

Disabled, Enabled

Indicate whether the peer end response test frames.

Table 2 Ethernet test (LSC board)

Field

Value

Description

Port

For example: Shelf1(ss)-29-12SLSC-3(RX1/TX1)

Displays the internal port name.

Status

Disabled, Enabled

Enables the test or not.

Send Flag

Disabled, Continue Mode

Sets the transmitting mode of frames.

Send Direction

UP, DOWN

Sets the transmitting direction of frames.

Test Frame Format

For example: Fix

Sets the packet type of test frame.

Test Frames Length

0, 1024, 9600

Sets the packet length of test frame.

Test Frames

1 to 65535

Sets the packet number of test frame.

Test Status

-

Queries the status of the test.

Tx Bytes

For example: 0

Statistics of test bytes sent.

Tx Error Frames

For example: 0

Statistics of error frames sent.

Rx Bytes

For example: 0

Statistics of received response bytes.

Rx Error Frames

For example: 0

Statistics of error received response frames.

Table 3 Service Connection Test

Field

Value

Description

Port

For example: VCTRUNK1

Selects the port to query the opposite port information.

Opposite Port Information

NE-board-VCTRUNK number

Displays the opposite port information that is queried.