In this user interface, you can query and set clock source switching conditions, and the status of switching condition enabling.
In the NE Explorer, choose . Click the Clock Source Switching Conditions tab.
Parameter |
Value |
Description |
|---|---|---|
NE Name |
For example: NE1 |
Displays the name of an NE. |
Clock Source |
For example: Internal Clock Source |
Indicates the name of the clock source. |
AIS Alarm |
Yes, No Default: No |
Sets the switching conditions enable status. When an AIS alarm occurs in the NE, the NE thinks that the corresponding clock source fails. |
B1 BER Threshold-Crossing |
Yes, No |
Sets the switching conditions enable status. When B1 error threshold-crossing occurs in the NE, the NE thinks that the corresponding clock source fails. |
CV Threshold-Crossing |
Yes, No |
Sets the switching conditions enable status. When CV threshold-crossing occurs in the NE, the NE thinks that the corresponding clock source fails |
CV Threshold |
- |
Displays the CV threshold. |
B2_EXC Alarm Generated |
Yes, No |
Sets the switching condition enable status. When B2_EXC alarm occurs in the NE, the NE thinks that the corresponding clock source fails. |
R_LOS, R_LOF and R_OOF/R_LOC Alarms |
Yes |
Displays the switching conditions enable status. When an R_LOS, R_LOF and R_OOF/R_LOC alarm occurs in the NE, the NE thinks that the corresponding clock source fails. The defaults is Yes, and you cannot set it. |
OTU1_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an OTU1_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
OTU2_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an OTU2_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
OTU3_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an OTU3_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU2_PM_AIS Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU2_PM_AIS alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU2_PM_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU2_PM_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU3_PM_AIS Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU3_PM_AIS alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
ODU3_PM_DEG Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an ODU3_PM_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
MS_AIS Alarm |
Yes, No Default: No |
Specifies the switching condition enable status. When an MS_AIS Alarm alarm occurs in the NE, the NE regards that the corresponding clock source fails. |
B2_EXC Alarm |
Yes, No Default: No |
Specifies the switching condition enabling status. When an B2_EXC alarm occurs in the NE, the NE regards that the corresponding clock source fails. |