Clock Source Switching Conditions

In this user interface, you can query and set clock source switching conditions, and the status of switching condition enabling.

Navigation Path

In the NE Explorer, choose Configuration > Clock > Clock Source Switching. Click the Clock Source Switching Conditions tab.

Parameter Description

Parameter

Value

Description

NE Name

For example: NE1

Displays the name of an NE.

Clock Source

For example: Internal Clock Source

Indicates the name of the clock source.

AIS Alarm

Yes, No

Default: No

Sets the switching conditions enable status. When an AIS alarm occurs in the NE, the NE thinks that the corresponding clock source fails.

B1 BER Threshold-Crossing

Yes, No

Sets the switching conditions enable status. When B1 error threshold-crossing occurs in the NE, the NE thinks that the corresponding clock source fails.

CV Threshold-Crossing

Yes, No

Sets the switching conditions enable status. When CV threshold-crossing occurs in the NE, the NE thinks that the corresponding clock source fails

CV Threshold

-

Displays the CV threshold.

B2_EXC Alarm Generated

Yes, No

Sets the switching condition enable status. When B2_EXC alarm occurs in the NE, the NE thinks that the corresponding clock source fails.

R_LOS, R_LOF and R_OOF/R_LOC Alarms

Yes

Displays the switching conditions enable status. When an R_LOS, R_LOF and R_OOF/R_LOC alarm occurs in the NE, the NE thinks that the corresponding clock source fails.

The defaults is Yes, and you cannot set it.

OTU1_DEG Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an OTU1_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails.

OTU2_DEG Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an OTU2_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails.

OTU3_DEG Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an OTU3_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails.

ODU2_PM_AIS Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an ODU2_PM_AIS alarm occurs in the NE, the NE regards that the corresponding clock source fails.

ODU2_PM_DEG Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an ODU2_PM_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails.

ODU3_PM_AIS Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an ODU3_PM_AIS alarm occurs in the NE, the NE regards that the corresponding clock source fails.

ODU3_PM_DEG Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an ODU3_PM_DEG alarm occurs in the NE, the NE regards that the corresponding clock source fails.

MS_AIS Alarm

Yes, No

Default: No

Specifies the switching condition enable status. When an MS_AIS Alarm alarm occurs in the NE, the NE regards that the corresponding clock source fails.

B2_EXC Alarm

Yes, No

Default: No

Specifies the switching condition enabling status. When an B2_EXC alarm occurs in the NE, the NE regards that the corresponding clock source fails.