Starting or Stopping the FC Service Test

By sending and receiving the test frame, you can verify whether an FC service line is normal.

Prerequisites

You must be logged in to the DUT successfully.

It is applicable to the 12LOM board.

Context

NOTE:

It is recommended that you do not clear the test data during the FC service test. Otherwise, the test data may be incorrect because of the clear operation.

Procedure

  1. In the NE Explorer, select a board and choose Configuration > FC Service Test from the Function Tree.
  2. Click the Testing tab.
  3. Click Start to start sending and receiving the test data. By observing the statistics of the test data packets, you can verify whether the line is normal.
  4. After you finish the verification, click Stop to end the test.

    NOTE:

    You can start and stop the FC service test for several times to verify whether the line is normal. If you get confused due to too much test data on the GUI, you can clear the test data before starting another test.

Follow-up Procedure

After the test is complete, clear the test data.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.