(Optional) Resetting the Connection Status

If you fail to connect to or log in to the DUT repeatedly, you can reset the test board by resetting the connection status, and perform the connection operation again.

Prerequisites

It is applicable to the 12LOM board.

Procedure

  1. In the NE Explorer, select a board and choose Configuration > FC Service Test from the Function Tree.
  2. Click the Testing tab.
  3. Click Link Reset and the Web LCT starts performing the initialization.
    If resetting the connection status is successful, the indicators next to the Link button and the Login button turn yellow. If resetting the connection status fails, the colors of these indicators remain unchanged.

Follow-up Procedure

Connect to the DUT.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.