This topic describes the board working mode and port working mode. A specific service signal flow of a board is available when the board working mode and port working mode are set to specific values.
The Web LCT supports a variety of board working modes.
| Board mode | Description |
|---|---|
NS1 mode |
The 12LQMS board functions as a line board that performs mutual conversion between the ODUk electrical signals and the optical signals at a WDM system-compliant standard wavelength. |
LQM mode |
The 12LQMS board functions as a tributary board that performs mutual conversion between the client-side signals and the optical signals at a WDM system-compliant standard wavelength. |
| Board mode | Description |
|---|---|
| Cascading |
|
| Non-Cascading |
|
A specific service signal flow of the 52TOM board is available only when both the board working mode and port working mode are set to specific values.
The 52TOM board should be set to the cascading or non-cascading mode. In addition, application scenarios such as the ODU0 or ODU1 mapping mode and tributary or tributary-line mode of the ports on the board should be set. As shown in Table 3, the 52TOM board supports 14 working modes.
Board Working Mode |
Port Working Mode |
Signal Flow |
Flow Chart |
|---|---|---|---|
Cascading |
ODU0 mode |
Any->ODU0[->ODU1] |
Service Signal Flow |
ODU0 tributary-line mode |
Any->ODU0->ODU1->OTU1 |
Service Signal Flow | |
ODU1 mode |
Any->ODU1 |
Service Signal Flow | |
ODU1 tributary-line mode |
Any->ODU1->OTU1 |
Service Signal Flow | |
None (not for ports) |
- |
- |
|
Non-Cascading |
ODU0 mode |
Any->ODU0[->ODU1] |
Service Signal Flow |
ODU0 tributary-line mode |
Any->ODU0->ODU1->OTU1 |
Service Signal Flow | |
ODU1 mode |
OTU1/Any->ODU1 |
Service Signal Flow | |
ODU1_ODU0 mode |
OTU1->ODU1->ODU0 |
Service Signal Flow | |
ODU1_ANY_ODU0 re-encapsulation mode |
OTU1->ODU1->Any->ODU0 |
Service Signal Flow | |
ODU1_ANY_ODU0_ODU1 re-encapsulation mode |
OTU1->ODU1->Any->ODU0->ODU1 |
Service Signal Flow | |
ODU1_ANY_ODU0_ODU1 re-encapsulation tributary-line mode |
OTU1->ODU1->Any->ODU0->ODU1->OTU1 |
Service Signal Flow | |
ODU1 tributary-line mode |
OTU1/Any->ODU1->OTU1 |
Service Signal Flow | |
None (not for ports) |
- |
- |
Board Working Mode |
Port Working Mode |
Mapping Path |
|---|---|---|
Cascading mode |
ODU1 tributary mode |
OTU1/Any->ODU1 |
ODU1 tributary-line mode |
OTU1/Any->ODU1->OTU1 |
|
Non-Cascading |
ODU1 tributary mode |
OTU1/Any->ODU1 |
ODU1 tributary-line mode |
Any->ODU1->OTU1 |
|
ODU1 tributary-line mode (electrical regeneration board) |
OTU1->ODU1->OTU1 |
The 54TOA and 54THA boards should be set to the ODU0 or ODU1 mapping mode and aggregation or non-aggregation mode of the ports on the board. As shown in Table 5, the 54TOA board supports 5 working modes. The 54THA board supports the same working modes as the 54TOA board.
Port Working Mode |
Signal Flow |
|---|---|
| ODU0 non-convergence mode | Any->ODU0 |
| ODU1 convergence mode | n*Any->ODU1 |
| ODU1 non-convergence mode | OTU1/Any->ODU1 |
ODUflex non-convergence mode |
Any->ODUflex |
| ODU1_ODU0 mode | OTU1->ODU1->ODU0 |
None (not for ports) |
- |
Port Working Mode |
Signal Flow |
|---|---|
ODU0 non-convergence mode |
Any->ODU0[->ODU1]->ODU2->OTU2 |
ODU1 non-convergence mode |
OTU1/Any->ODU1->ODU2->OTU2 |
ODU1_ODU0 mode |
OTU1->ODU1->ODU0[->ODU1]->ODU2->OTU2 |
ODUflex non-convergence mode |
Any->ODUflex->ODU2->OTU2 |
ODU2 non-convergence mode |
Any->ODU2->OTU2 |
None (not for ports) |
- |