This section describes the process of configuration between station A and station C. For the configuration of other stations, refer to the description for station C.
The ne-level optical cross-connection is adopted. Before configuration, fiber connection on the Web LCT system should be completed.
The path between FIUs is created in the example. The FIUs are the fixed edge point. Hence, the edge point does not need to be configured after fiber connection. Otherwise the corresponding ports need be configured as edge points.
For details of fiber connection, refer to Creating Fibers.
| Direction | Source NE | Source Port | Sink NE | Sink Port |
|---|---|---|---|---|
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-1-FIU-3(TC) | NE180 | Shelf0(Subrack)-3-OAU1-1(IN) |
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-3-OAU1-4(OUT) | NE180 | Shelf0(Subrack)-3-OAU1-5(RDC) |
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-3-OAU1-4(OUT) | NE180 | Shelf0(Subrack)-5-WSD9-1(IN) |
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-5-WSD9-10(DM8) | NE180 | Shelf1(Subrack1)-5-RMU9-10(AM8) |
| Single-Fiber Unidirectional | NE180 | Shelf1(Subrack1)-5-RMU9-11(TOA) | NE180 | Shelf1(Subrack1)-3-OAU1-1(IN) |
| Single-Fiber Unidirectional | NE180 | Shelf1(Subrack1)-3-OAU1-5(TDC) | NE180 | Shelf1(Subrack1)-3-OAU1-5(RDC) |
| Single-Fiber Unidirectional | NE180 | Shelf1(Subrack1)-3-OAU1-4(OUT) | NE180 | Shelf1(Subrack1)-1-FIU-3(RC) |
| Single-Fiber Unidirectional | NE180 | Shelf2(Subrack2)-1-LSX-1(OUT) | NE180 | Shelf0(Subrack)-9-RMU9-3(AM1) |
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-9-RMU9-11(TOA) | NE180 | Shelf0(Subrack)-14-OAU1-1(IN) |
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-14-OAU1-5(TDC) | NE180 | Shelf0(Subrack)-14-OAU1-5(RDC) |
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-14-OAU1-4(OUT) | NE180 | Shelf0(Subrack)-15-FIU-3(RC) |
| Single-Fiber Unidirectional | NE180 | Shelf0(Subrack)-5-WSD9-9(DM7) | NE180 | Shelf1(Subrack1)-10-RMU9-10(AM8) |
| Single-Fiber Unidirectional | NE180 | Shelf1(Subrack1)-10-RMU9-11(TOA) | NE180 | Shelf1(Subrack1)-15-OAU1-1(IN) |
| Single-Fiber Unidirectional | NE180 | Shelf1(Subrack1)-15-OAU1-5(TDC) | NE180 | Shelf1(Subrack1)-15-OAU1-5(RDC) |
| Single-Fiber Unidirectional | NE180 | Shelf1(Subrack1)-15-OAU1-4(OUT) | NE180 | Shelf1(Subrack1)-16-FIU-3(RC) |
| Direction | Source NE | Source Port | Sink NE | Sink Port |
|---|---|---|---|---|
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-1-FIU-3(TC) | NE182 | Shelf0(Subrack)-3-OAU1-1(IN) |
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-3-OAU1-5(TDC) | NE182 | Shelf0(Subrack)-3-OAU1-5(RDC) |
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-3-OAU1-4(OUT) | NE182 | Shelf0(Subrack)-5-WSD9-1(IN) |
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-5-ROAM-2(EXPO) | NE182 | Shelf0(Subrack)-9-ROAM-3(EXPI) |
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-9-ROAM-4(OUT) | NE182 | Shelf0(Subrack)-14-OAU1-1(IN) |
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-14-OAU1-4(OUT) | NE182 | Shelf0(Subrack)-15-FIU-3(RC) |
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-5-ROAM-5(DM) | NE182 | Shelf1(Subrack1)-1-D40-1(IN) |
| Single-Fiber Unidirectional | NE182 | Shelf1(Subrack1)-1-D40-5(D04) | NE182 | Shelf1(Subrack1)-4-LSX-1(IN) |
| Single-Fiber Unidirectional | NE182 | Shelf1(Subrack1)-1-D40-6(D05) | NE182 | Shelf1(Subrack1)-5-LSX-1(IN) |
| Single-Fiber Unidirectional | NE182 | Shelf0(Subrack)-14-OAU1-5(TDC) | NE182 | Shelf0(Subrack)-14-OAU1-5(RDC) |
| Single-Fiber Unidirectional | NE182 | Shelf1(Subrack1)-6-LSX-1(OUT) | NE182 | Shelf0(Subrack)-9-ROAM-9(A04) |