After Layer 2 attributes of an Ethernet interface are set, the interface can be used for connecting to the client-side equipment at the edge of an SDH network or for forwarding Ethernet packets within the SDH network. The Layer 2 attributes
of an Ethernet interface define the related information of the data link layer.
Prerequisites
In Basic Attributes, Port Mode must be set to Layer 2.
Procedure
- In the NE Explorer, select an NE and choose from
the Function Tree.
- Click the Layer 2 Attributes tab.
- Select the desired port and set the parameters as required.
NOTE: Note the following issues during parameter settings:
- QinQ Type Domain can be set only when Encapsulation Type is QinQ.
- TAG can be set only when Encapsulation Type is 802.1Q.
- Default VLAN ID and VLAN Priority can be set only when Encapsulation Type is 802.1Q or Null.
- Click Apply. Click OK, The Operation Result dialog box is displayed indicating that the operation is successful.
- Click Close.
Copyright © Huawei Technologies Co., Ltd.