Application of the Lower-Order PRBS Function

The lower-order PRBS function supports the PRBS test in the cross-connect direction.

Figure 1 shows the signal flow of a lower-order PRBS test.

Figure 1 Signal flow of a lower-order PRBS test

Lower-Order PRBS Test in the Cross-Connect Direction

The lower-order PRBS test in the cross-connect direction is used to check whether the corresponding cross-connect section and line section are normal after tributary services are accessed. The board transmits fixed PRBSs in the cross-connect direction on the tested path and receives the PRBSs in the downstream direction of the tested path. See Figure 2. When you perform a PRBS test in the cross-connect direction, note the following:

Figure 2 Lower-order PRBS test in the cross-connect direction