In this user interface, you can set Ethernet port performance monitoring parameters. You can make the settings on the basis of 30-second, 30-minute and cycle-definable.
In the NE Explorer, click the Ethernet board and select from the Function Tree. Click the History Control Group tab.
In the NE Explorer, click the NE and choose from the Function Tree.
Field |
Value |
Description |
|---|---|---|
Sampling Period |
30-Second, 30-Minute, Custom Period 1, Custom Period 2 |
Selects the monitor period. |
Monitored Object |
|
The internal port of the NE Ethernet interface board. |
Sampling Period(s) |
30 to 86400 |
The value range and default value depend on the boards and the sampling periods. |
Number of Items |
1 to 50 Default: 50 |
Number of items can be queried at one time. Up to 50 items can be can queried at one time. |
Monitor Status |
Enabled, Disabled |
Sets whether to monitor. |
Field |
Value |
Description |
|---|---|---|
Object |
30-Second, 30-Minute, Custom Period 1, Custom Period 2 |
Indicates the monitoring period. |
Enable |
Enabled, Disabled |
Sets the enable status of monitoring. |
Period Length (s) |
For example: 900 |
Sets duration for the Custom Period 1 or Custom Period 2. The period must be the integer multiple of 30 seconds. |
History Register Count |
1 to 50 |
Sets the number of the history registers. |
RMON Monitor Start Time |
For example: 05/19/2010 16:24:08 |
Sets the start time of RMON monitor. |