In this user interface, you can set Ethernet port alarm data. You can set whether to enable reporting and monitoring, and set the upper/lower threshold of alarm count.
In the NE Explorer, click the Ethernet board and select from the Function Tree. Click the Alarm Group tab.
Field |
Value |
Description |
|---|---|---|
Port/Path |
|
The port or path of the alarm. |
Alarm Name |
For example: DropEvent |
Monitors alarms of the port by the Ethernet service type. |
Sampling Interval(s) |
5 to 600 |
The period of sampling the port data. |
Report Mode |
Report ALL Report in Case of Lower Threshold-Crossing Report in Case of Upper Threshold-Crossing |
Sets whether to report alarm when the alarm number exceeds the upper or lower threshold, or report at any alarm. |
Upper Threshold |
1 to 4294967295 |
Sets the upper threshold of alarm count. |
Lower Threshold |
0 to 4294967294 |
Sets the lower threshold of alarm count. |
Monitor Status |
Enabled, Disabled Default: Disabled |
Sets whether to monitor. |