On this user interface, you can query and modify the attributes and status of the SNCTP services.
In the NE Explorer, select the NE and choose from the Function Tree.
Button |
Description |
||
|---|---|---|---|
Query Protection Group |
Queries the existing SNCTP protection groups. |
||
Query Switch Status |
Queries the channel protection status. |
Items |
Description |
|---|---|
Query |
Queries the channel protection status. |
Clear |
Clears switching for the selected channel. |
Force to Protection |
Forces the service to switch from the working channel to the protection channel. This switching is performed regardless of the protection channel state, unless the protection channel is satisfying a higher priority bridging request. |
Force to Working |
Forces services to switch from the protection channel to the working channel. This switching is performed regardless of the working channel state, unless the working channel is satisfying a higher priority bridging request. |
Manual to Protection |
Performs manual switching from the working channel to the protection channel. If the protection channel is normal, the switching takes place. If the protection channel has a failure or must satisfy higher priority switching, the switching does not take place. |
Manual to Working |
Performs manual switching from the protection channel to the working channel. If the working channel is normal, the switching takes place. If the working channel has a failure or must satisfy higher priority switching, the switching does not take place. |
Lockout of Protection |
The switching request for the port is denied, but the reversion of switching is allowed. |
Field |
Value |
Description |
|---|---|---|
Protect Group ID |
For example: 1 |
Displays the protection group ID. |
Revertive Mode |
Revertive, Non-Revertive |
Displays the revertion mode. Whether the working service is switched back from the protection service after it returns normal. |
WTR Time (s) |
300 to 720 |
Sets the wait-to-restore time. Refer to the period of time starting when it is detected the working service returns to normal and ending when the working service is switched back after the protection switching. If the revertive mode is non-revertive, skip this step. |
Working Channel Hold-Off Time (100 ms) |
For example: 0 to 100, in the unit of 100 milliseconds |
Sets a period of time starts when the system detects signal degrade and ends when service switching occurs, so as to avoid duplicate switching when the service status is unstable. Sets 100 milliseconds as the unit time for switching. 5 indicates that the hold-off time is 500 milliseconds. |
Working Channel - Switching Condition |
TIM, EXC, SD, UNEQ Default: Null |
Sets the startup conditions that trigger service protection switching. |
Protection Channel Hold-Off Time (100 ms) |
For example: 0 to 100, in the unit of 100 milliseconds |
Sets a period of time starts when the system detects signal degrade and ends when service switching occurs, so as to avoid duplicate switching when the service status is unstable. Sets 100 milliseconds as the unit time for switching. 5 indicates that the hold-off time is 500 milliseconds. |
Protection Channel - Switching Condition |
TIM, EXC, SD, UNEQ Default: Null |
Sets the startup conditions that trigger service protection switching. |
Switching Status |
Lockout, Forced Switching, Manual Switching, WTR, SD Switching, SF Switching, Unknown, Normal |
Displays the switching status of the protection group. |
Active Channel |
For example: Working Unit |
Displays what the current protection group selectively receives: the working or the protection service. |
Service Origin |
Create Manually, Intelligently Generate |
Displays the creation mode of the service. When the value is Intelligently Generate, the user can only query the service, and cannot modify the service settings. |
Timeslot Mapping |
For example: Slot ID-Board Name-Optical Interface No. (name)-VC4:1 |
Displays the timeslots that are mapped to the working and protection units. |
Unit Type |
Working Channel, Protection Channel |
Displays the working channel and the protection channel of the protection unit. |
Status |
Normal, SF, SD, Unknown |
Displays the current status of the working and protection units. |
Working Time Slot Range |
1 to 64 |
Sets the timeslot range. |
Working Channel |
|
Selects the working channel. |
Protection Time Slot Range |
1 to 64 |
Sets the timeslot range. |
Protection Channel |
|
Selects the protection channel. |
Working Channel Timeslot Mapping |
|
Displays the working channel timeslot mapping. |
Protection Channel Timeslot Mapping |
|
Displays the protection channel timeslot mapping. |