OAM Error Frame Monitor

In this interface, you can configure and query parameters related to the OAM error frame monitor of an Ethernet port.

Navigation Path

In the NE Explorer, click the NE and choose Configuration > Packet Configuration > Ethernet OAM Management > Ethernet Port OAM Management. Then, click the OAM Error Frame Monitor tab.

Parameters

Table 1 Descriptions of the parameters for OAM Error Frame Monitor

Field

Value

Description

Port

slot number-board name-port number(port name)

Display the function port for the OAM.

Error Frame Monitor Window (ms)

1000-60000, 100 as the spacing

Set the time window for monitoring error frames.

An alarm is reported if the number of error frames that occur during the Error Frame Monitor Window (ms) period exceeds the specified Error Frame Monitor Threshold (frames).

Error Frame Monitor Threshold (frames)

1-4294967295, 1 as the spacing

Set the threshold for monitoring the error frames.

Error Frame Period Window (frames)

1488-892800000, 1 as the spacing

Set the window for monitoring error frame period.

An alarm is reported if the number of error frames that occur during the Error Frame Period Window (frames) period exceeds the specified Error Frame Monitor Threshold (frames).

Error Frame Period Threshold (frames)

1-error frame period window, 1 as the spacing

Set the threshold for monitoring the error frame period.

Error Frame Second Window (s)

10-900, 1 as spacing

Set the time window for monitoring error frame seconds.

If any error frame occurs in one second, this second is an error frame second.

An alarm is reported if the number of error frame seconds in the Error Frame Second Window (s) period exceeds the specified Error Frame Second Threshold (s).

Error Frame Second Threshold (s)

1-error frame second window, 1 as the spacing

Set the threshold for monitoring the error frame seconds.

Error Frame Signal Periodic Monitor Window (Entries)

1-60, 1 as the spacing

Set the window for periodically monitoring error frame signals.

An alarm is reported if the number of error frame signals in the Error Frame Signal Periodic Monitor Window (Entries) exceed the Error Frame Signal Periodic Monitor Threshold (Entries).

Error Frame Signal Periodic Monitor Threshold (Entries)

1-7500000000, 1 as the spacing

Set the threshold for periodically monitoring the error frame signals.


Huawei Proprietary and Confidential