Path Binding

In this user interface, you can configure or query the path binding.

Navigation Path

In the NE Explorer, select an NE and choose Configuration > Path Binding from the Function Tree. The user interface of path binding management is displayed.

Buttons

Button

Description

Configure

Clicks Configure to configure path binding.

Parameters

Field

Value

Description

Port

  • Equipment that supports the master and slave shelf management: NE name-shelf ID(shelf name)-slot number-board name-port number(port name)
  • Equipment that does not support the master and slave shelf management: NE name-slot number-board name-port number(port name)

Displays available optical interfaces.

Direction

Uplink, Downlink

Displays the sink of Ethernet services.

Path Binding

ODU1 (1, 2, 3, 4)

Displays the bound paths.

Binding Path Count

1, 2, 3, 4

Displays the number of bound paths.

Slot ID

  • Equipment that supports the master and slave shelf management: shelf ID(shelf name)-slot number-board name
  • Equipment that does not support the master and slave shelf management: slot number-board name

Displays the board that realizes path binding.

Port ID

For example, 151(IMP1/IMP1)

Displays ports available for the board.

Available Bound Path

For example, ODU1-1

Displays available paths.

Selected Bound Path

For example, ODU1-1

Displays the selected paths.
NOTE:
The bound path ODU1-1 is required.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.