Clock Attribute Configuration

Navigation Path

In the NE Explorer, select an NE and choose Configuration > Clock > Clock Attribute Configuration from the Function Tree.

In the NE Explorer, select a board and choose Clock > Clock Attribute Configuration from the Function Tree.

Parameters

Field

Value

Description

Clock Board

For example: Shelf8(Slave shelf8)-5-53TDX(STND)

Chooses a clock board.

Port

For example: Shelf8(Slave shelf8)-5-53TDX(STND)-4(RX2/TX2)

Displays the clock port.

Synchronous Clock Enabled

Disabled, Enabled

Default: Disabled

Determines whether to enable lock synchronization. Set the parameter to Enabled if clock synchronization is required.

When this parameter is set to Enabled, service clocks are synchronized with NE clocks. When the parameter is set to Disabled, service clocks will not be synchronized with NE clocks.

Synchronous/Asynchronous Mode

Synchronous, Asynchronous

Default: Asynchronous

Sets the clock port to work in synchronous mode or asynchronous mode.


Huawei Proprietary and Confidential