In this user interface, you can set the maximum or minimum attenuation rate for optical ports and path use status. You can set or query parameters related to working wavelengths, including fixed band and the parity of working band.
Field |
Value |
Description |
|---|---|---|
Optical Interface/Channel |
|
Displays the optical interface. |
Optical Interface Name |
For example: IN1/OUT1 |
Displays default names. Do not modify this field. |
Optical Interface Attenuation Ratio (dB) |
0-40 |
Sets the attenuation ratio of the optical port. |
Max. Attenuation Ratio (dB) |
For example: 40 |
Displays the maximum attenuation ratio. If the actual attenuation ratio is greater than this value, the output power is so small that it may cause decrease of the optical signal noise ratio (OSNR) at the receive end. |
Min. Attenuation Ratio (dB) |
For example: 5 |
Displays the minimum attenuation ratio. If the actual attenuation ratio is smaller than this value, the output power is so large that it may cause decrease of the OSNR at the receive end. |
Path Use Status |
Used, Unused Default: Used |
Sets whether the path is being used. |
Actual Band |
C |
Displays the current working band of the path. Currently only C band is supported. |
Configure Band |
C |
Configures the working band of the port. |
Threshold of Input Power Loss (dBm) |
For example: -50 |
Input power that is smaller than this value cannot be determined. |
Actual Working Band Parity |
Even, Odd |
Displays the parity of the current working band of the port. Currently only even band is supported. |
Configure Working Band Parity |
Even, Odd |
Configures the parity of the working band of the port. Currently only even band is supported. |