Optical Supervisory Channel Board

In this user interface, you can set laser status and loopback, and query the wavelengths of an optical port.

Parameters

Field

Value

Description

Optical Interface/Channel

  • Equipment that supports the master and slave shelf management: NE name-shelf ID(shelf name)-slot number-board name-port number(port name)
  • Equipment that does not support the master and slave shelf management: NE name-slot number-board name-port number(port name)

Displays current optical port/channel number.

Optical Interface Name

For example: RM/TM

Sets/displays the optical port name.

Loopback

Non-Loopback, Inloop, Outloop

Default: Non-Loopback

You can set optical port loopback for troubleshooting or testing.

Laser Status

Open, Close

Sets the laser status.

Applicable boards: SC1, SC2, TC1 and TC2.

Actual Wavelength No./Wavelength (nm)/Frequency (THz)

For example: 1/1510.00/198.54

Displays the working wavelength of the optical port.

Actual Band Type

C, CWDM

Displays the band of the current working wavelength.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.