Automatic Disabling of NE Function

In this user interface, you can set automatic disabling of NE functions, and the time for automatic disabling.

Navigation Path

In the NE Explorer, select an NE and choose Configuration > Automatic Disabling of NE Function from the Function Tree.

NOTICE:

To avoid ECC communication interruption caused by loopback, the Web LCT disables the loopback in five minutes by default. If you want to specify a different time period for loopback automatic disabling, you can set the Auto Disabling Time parameter.

Parameters

Field

Value

Description

Operation Type

For example: Optical/Electrical/CPRI Interface Loopback

Displays the operations that can be automatically cleared.

Auto Disabling

Range: Enabled, Disabled.

Default: Enabled

Sets whether the NE functions are to be disabled automatically.

Auto Disabling Time (min)

1 to 2880

Sets the time after which the NE functions will be disabled automatically.

NOTE:

When the Operation Type parameter is set to IPA Disable, the value of the Auto Disabling Time (min) parameter ranges from 1 to 60.