In this user interface, you can query the power consumption of NEs.
Choose from the main menu (traditional style); alternatively, double-click Fix-Network NE Configuration in Application Center and choose from the main menu (application style). Select the NE Power tab.
See the Hardware Description of related NEs for details about the engineering survey requirements of NE Power Consumption Threshold(W).
Field |
Value |
Description |
|---|---|---|
No. |
Example: 1 |
Indicates the serial number of the NE equipment. |
NE/Shelf Name |
Example: NE732 |
Indicates the name of the monitored unit (NE or Shelf). For the WDM equipment, the monitor unit is the shelf; for the non-WDM equipment, the monitored unit is the NE. |
NE/Shelf Type |
For example: RTN900 |
Indicates the type of the equipment. |
NE Power Consumption Threshold(W) |
Values vary with the NE version. For details, see the Hardware Description of related NEs. |
The NE power consumption threshold is a default value that is a bit smaller than the maximum power consumption of the NE. NOTICE:
NEs may consume too much power and stop working if this parameter is set to a value greater than the maximum NE power consumption. |
NE Nominal Power Consumption(W) |
Example: 777.000 |
Indicates the total nominal power consumption of all boards on the NE. |
NE Current Power Consumption(W) |
Example: 716.000 |
Indicates the actual power consumption when the NE runs. It is computed based on the actual voltage and current. |
NE Mean Power Saved(W) |
Example: 61.000 |
Indicates the mean power saved for an NE. This parameter is dynamically changed. It indicates the power saved when the energy saving function is enabled during a period. |