Phase-Locked Source Output by External Clock

In this user interface, you can set the external clock source attributes of the 2M phase-locked source. You can set the output mode, output timeslot, output threshold, failure condition and failure action of the 2M phase-locked source external clock.

Navigation Path

In the NE Explorer, click an NE and choose Configuration > Clock > Physical Layer Clock > Phase-Locked Source Output by External Clock from the Function Tree.

NOTE:
The parameters available for configuration vary with the type of equipment.

Parameters

Field

Value

Description

2M Phase-Locked Source Number

For example: External Clock Source 1

Displays the serial numbers of the output external clock sources of an NE.

External Clock Output Mode

2M Hz, 2M Bit/s, 64kHz+8kHz

Sets the 2M clock signal output mode of the external source.

External Clock Output Timeslot

ALL, SA4, SA5, SA6, SA7, SA8

Default: ALL

Sets the timeslot occupied by SSM in the output 2M clock signal.

For example, if the value is SA4, it indicates that the SSM is transmitted by using the fourth bit among the eight bits in the first timeslot TS0 of the four consecutive even frames. If the value is SA5, it indicates that the SSM is transmitted by using the fifth bit among the eight bits in the first timeslot TS0 of the four consecutive even frames.

SSM can only be output in 2M Bit/s output mode.

External Source Output Threshold

Threshold Disabled, Not Inferior to G.813 SETS Signal, Not Inferior to G.812 Local Clock Signal, Not Inferior to G.812 Transit Clock Signal, Not Inferior to G.811 Clock Signal

Default: Threshold Disabled

Sets the quality standard for external source output and stop outputting clocks when the standard is inferior to the preset threshold.

2M Phase-Locked Source Failure Condition

AIS, LOF, AIS OR LOF, No Failure Condition

Default: No Failure Condition

Sets the conditions for judging whether the 2M phase-locked source fails or not. If AIS OR LOF is selected, either of the two alarms will cause 2M phase-locked source failed.

2M Phase-Locked Source Failure Handling

2M Output S1 Byte Unavailable, Send AIS, Shut Down Output

Default: Shut Down Output

Sets the action taken when the 2M phase-locked source fails. When the 2M phase-locked source fails, external clock output is performed according to the parameter setting.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.